OBUbeD
LifeQuality Jeweller
Wireless temperature, humidity, and CO₂ monitor
yA5lgs
9td1WlCommunication
Jeweller communication technology
Proprietary wireless communication technology to transmit events.
It features:
- Two-way communication.
- Protection against spoofing.
- Block encryption with a dynamic key.
- Instant notifications.
- Remote configuration via the Ajax apps.
Frequency bands
866.0–866.5 MHz
868.0–868.6 MHz
868.7–869.2 MHz
905.0–926.5 MHz
915.85–926.5 MHz
921.0–922.0 MHz
Depends on the sales region.
Maximum effective radiated power (ERP)
up to 20 mW
Automatic power regulation to reduce power consumption and radio interference.
Radio signal modulation
GFSK
Radio communication range
up to 5,600 ft
Between the detector and a hub/range extender in an open space.
Encrypted radio communication
All the data stored and transmitted are protected by block encryption with a dynamic key.
Radio frequency hopping
To prevent radio interference and jamming.
Wings communication technology
Proprietary wireless communication technology for backup connection with the hub (or radio signal range extender).
It features:
- Two-way communication.
- Block encryption with a dynamic key.
- Re-uploading data packets in case of error during data transfer.
Frequency bands
866.0–866.5 MHz
868.0–868.6 MHz
868.7–869.2 MHz
905.0–926.5 MHz
915.85–926.5 MHz
921.0–922.0 MHz
Depends on the sales region.
Radio communication range
up to 5,600 ft
Between the detector and a hub/range extender in an open space.
Encrypted radio communication
All the data stored and transmitted are protected by block encryption with a dynamic key.
Radio frequency hopping
To prevent radio interference and jamming.
Sensitive elements
Temperature and humidity sensor
CO2 (carbon dioxide) sensor
Temperature measurement
Sensitive element
Digital temperature and humidity sensor
Values in the Ajax apps are updated depending on the frequency of the "hub—detector" polling interval, but not less than once per minute.
Measurement range
from 32°F to 122°F
The value is available in the device States in the Ajax app.
Measurement accuracy
±0.36°F
Measurement pitch
0.18°F
The minimum temperature change value recorded in the Ajax apps.
Comfort level from 57 to 70°F
Temperature range
Humidity measurement
Sensitive element
Digital temperature and humidity sensor
Values in the Ajax apps are updated depending on the frequency of the "hub—detector" polling interval, but not less than once per minute.
Measurement range
from 0% to 100%
The value is available in the device States in the Ajax app.
Measurement accuracy
±1.8%
Measurement pitch
1%
The minimum humidity change value recorded in the Ajax app.
Comfort level from 30 to 60%
Humidity range
Carbon dioxide (CO₂) concentration measurement
Sensitive element
digital carbon dioxide sensor
Values in the Ajax apps are updated depending on the frequency of the "hub—detector" polling interval, but not less than once per minute.
Measurement range
from 400 to 10,000 ppm
The value is available in the device States in the Ajax app.
Air quality assessment levels
normal air: up to 1000 ppm
moderately polluted air: from 1000 to 1400 ppm
polluted air: from 1400 to 2000 ppm
critically polluted air: more than 2000 ppm
Effects on well-being:
from 1000 to 2500 ppm— lethargy;
from 2500 to 5000 ppm—possible adverse health effects;
5000 ppm and above—the maximum permissible concentration during an 8-hour working day.
Measurement accuracy
±30 ppm or ±3%
When the CO₂ concentration is less than 5,000 ppm. For higher concentrations, the measurement error increases.
Measurement pitch
1 ppm
The minimum value of the change in carbon dioxide concentration recorded in the Ajax app.
Acceptable level to 1100 ppm
CO2 range
Additional features
Charts
of temperature, humidity, and carbon dioxide concentration
Available in the Ajax apps. The data is updated in real time. Measurements are stored for up to 2 years.
Discrete value: 1 minute.
LED indication
green: Normal air
yellow: Slightly polluted air
red: Polluted air
purple: Сritically polluted air
The LED indicator on the device enclosure lights up in the event of a critical change in air quality. The user can also turn on the indication by touching the touch sensitive button on the front panel of the detector.
Automatic calibration
once every 1–14 days
The detector selects a calibration interval depending on the circumstances and automatically calibrates the carbon dioxide sensor. In normal conditions (ventilated room), manual calibration is not required. The digital humidity and temperature sensor does not require additional calibration.
Manual calibration
is run in the Ajax apps. Suitable for unventilated rooms. We recommend calibrating the detector once every 2-3 weeks in such rooms.
Scenarios
reactions to changes in temperature, humidity, and carbon dioxide concentration
For example, turning on plenum ventilation if the air quality deteriorates.
Backup memory
up to 3 days
If the detector loses communication with the hub (or radio signal range extender), it stores all measured values. After the connection is restored, all values are sent to the Ajax app.
Recommendations
The device is designed only for indoor installation at any height. It is not necessary to use the SmartBracket mounting panel.
The detector can be placed on a table or shelf.
Sabotage protection
Accelerometer
Notifies on attempts to tear off the detector from a surface, remove it from the mounting panel, or move the detector if it is placed on a table or shelf.
Protection against spoofing
device authentication
Communication loss detection
within 36 seconds
The detection time depends on the Jeweller or Jeweller/Fibra settings.
Power supply
2 × CR123A battery
Up to 2.5 years of autonomous operation.
Enclosure
Dimensions
3.03″ × 3.03″ × 1.36″
Weight
4.48 oz
Operating temperature range
from 32°F to 122°F
Operating humidity
up to 85%
Protection class
IP50
Colours
Black
White
Complete set
LifeQuality Jeweller
SmartBracket mounting panel
2 × CR123A battery (pre-installed)
Installation kit
Quick start guide
hQt5e6
LifeQuality Jeweller
LifeQuality Jeweller
Radio Equipment Directive (RED)
Certificate issued by MiCOM Labs
EN 300 220-1 V3.1.1
EN 300 220-2 V3.2.1
Restriction of Hazardous Substances Directive (RoHS)
Test report issued by Shenzhen NTEK Testing Technology Co
EN IEC 63000:2018
Electromagnetic Compatibility Directive (EMC)
Certificate issued by MiCOM Labs
EN 301 489-1 V2.2.3
EN 301 489-3 V2.1.1
EN 55032:2015+A11:2020
EN 55035:2017+A11:2020
Low Voltage Directive (LVD)
Certificate issued by MiCOM Labs
EN 62479:2010
EN IEC 62368-1:2020+A11:2020
FCC ID
Certificate issued by MiCOM Labs
2AX5VLIFEQUA-NA
IC ID
Certificate issued by MiCOM Labs
26860-LIFEQUANA1
PSTI UK
Schedule 1