Wireless fire detector with temperature sensor that monitors security in the room twenty four hours a day and immediately notifies of smoke and sharp jumps in temperature.

FAQ

How to activate the siren at FireProtect or FireProtect Plus fire detector with DoubleButton

This option is not provided.

Where do I need to install the FireProtect detector?

Installation of a smoke detector at the highest point of the ceiling at a minimum distance of one meter from the source of lighting and the exhaust ventilation pipe is recommended. If ceiling beams run across the ceiling and protrude 30 cm from the ceiling level, then at least one detector should be placed between every pair of beams.

What is Smoke Sensor Self Test

Test is available at menu:

  1. Ajax appDevices HubFilled-MFireProtect / FireProtect PlusSettings Settings-MSmoke Sensor Self Test

Detector and smoke chamber test. As a result, the Ajax application will receive a notification specifying whether the detector and its smoke chamber are OK and whether cleaning is required.