Language:

Partner Portal

FireProtect 2 (Heat/Smoke) Jeweller

FireProtect 2 (Heat/Smoke) Jeweller

Wireless fire detector with heat and smoke sensors

Product versions

FireProtect 2 RB (Heat/Smoke) Jeweller

FireProtect 2 RB (Heat/Smoke) Jeweller

Up to 7 years of operation on replaceable batteries

FireProtect 2 SB (Heat/Smoke) Jeweller

FireProtect 2 SB (Heat/Smoke) Jeweller

Up to 10 years of operation on sealed batteries

Accuracy through steam, dust, and time

FireProtect 2 (Heat/Smoke) Jeweller is a battery-powered fire detector designed to protect homes without false alarms. Its dustproof and insect-resistant smoke chamber, dual-spectrum optical sensor, proprietary software algorithm, and two thermistors deliver best-in-class detection accuracy. If danger is real, an 85 dB siren, two interconnection types, and instant push notifications in Ajax apps make the alarm impossible to ignore. With thoughtful design, self-monitoring, and early low battery alerts, the device ensures uninterrupted protection with fewer maintenance visits.

FireProtect 2 Jeweller features in two minutes

Wireless fire detector with heat, smoke, and/or CO sensors

Watch on Youtube

Discover Ajax fire and life safety category

Watch Ajax Special Event to learn what makes Ajax fire and life safety category unique

Watch on Youtube

Key features

Two types of interconnected fire alarm

Interconnected fire alarm

Primary: via an Ajax hub, alarm within 20 s

Versions with different battery types

Replaceable

Sealed

Sensors

Heat

smoke-sensor-s

Smoke

Remote control

Remote control and configuration

85 dB built-in siren

85 dB built-in siren

Compliance with standards

Informative push notifications

Ajax logo
10:00

Ajax

Home: signs of smoke detected, FireProtect 2 in Kitchen

Ajax logo
10:00

Ajax

Home: received photo by scenario Smoke in the kitchen, MotionCam (PhOD) in Kitchen

Up to 5,550 ft

Communication range with an Ajax hub in open space

Jeweller radio communication

Jeweller radio communication

Power adjustment

Two colors

Two colors

Hassle-free installation

1

QR-code

2

SmartBracket

3

App

Operates as part of the Ajax system or as a standalone device

Smartbracket

SmartBracket

with an adjustable rotation angle

Dual-spectrum optical smoke sensor

to filter out false alarms

Dual-spectrum optical smoke sensor
Dustproof and insect-resistant smoke chamber

Dustproof and insect-resistant smoke chamber

Device compatibility

Awards

PSI 2025

Wherever there is a risk of fire

Kitchen

Kitchen

Living room

Living room

Bedroom

Bedroom

Hall

Hall

Home office

Home office

Pantry

Pantry

Basement

Basement

Barn

Barn

Workshop

Workshop

Discover future-proof hardware

Smoke chamber with a dual-spectrum optical sensor

Smoke chamber with a dual-spectrum optical sensor

Two thermistors

Two thermistors

Test/Mute mechanical button

Test/Mute mechanical button

LED indication of detector states

LED indication of detector states

Batteries

Batteries

85 dB siren

85 dB siren

SmartBracket mounting panel

SmartBracket mounting panel

Detection without compromise

Smoke detection

The detector is designed to ensure accurate smoke detection over time. A dustproof and insect-resistant smoke chamber features a dual-spectrum optical sensor. It uses blue and infrared LEDs to measure the concentration of combustion products and the size of their volatile particles. The HazeFlow 2 algorithm then analyzes the collected data to distinguish smoke from false triggers, such as vapor or steam. If the analysis indicates a real fire, the detector instantly raises an alarm.

Smoke detection

Heat detection

FireProtect 2 (Heat/Smoke) Jeweller is equipped with two A1R-class thermistors to detect smokeless fires. Positioned outside the enclosure, the thermistors immediately register if the temperature rises by 50 °F within a minute or exceeds a threshold of 147 °F. This design ensures the fastest possible response, even when a threat grows gradually.

Heat detection

Stable performance for a decade

FireProtect 2 (Heat/Smoke) Jeweller delivers up to 10 years of autonomous operation thanks to pre-installed batteries, sealed or replaceable. Real-time battery status is always visible in Ajax apps, so there is no need for unnecessary maintenance visits. If the battery runs low, users receive push notifications and on-site LED and sound alerts 30 days before the full discharge.

SB version

SB version

Up to 10 years of operation

on sealed batteries

RB version

RB version

Up to 7 years of operation

on replaceable CR123A batteries

Clear alerts for faster response

In addition to LED indication, FireProtect 2 (Heat/Smoke) Jeweller features impossible-to-ignore sound alerts, thanks to a powerful 85 dB siren with distinct tones. Each indication corresponds to a specific event, drawing attention and helping users react accordingly.

Sound and LED indications

Smoke or heat alarms

Malfunction

Low battery

End of life

Sound and LED indications

Enhanced wireless interconnection

To spread an alarm across the facility as quickly as possible, FireProtect 2 (Heat/Smoke) Jeweller supports primary and fallback1 interconnection with other on-site fire detectors. The primary one operates via a hub: the detectors alert the hub to a threat, which then activates the sirens of all fire detectors on-site. The process takes just 20 seconds — three times faster than standards require. If hub communication is lost, the fallback interconnection takes over. The initiating fire detector directly communicates with other devices, raising the alarm across the system within a minute. Even in the worst-case scenario, people on-site are warned and have time to act.

Primary interconnection via a hub

20 seconds to activate up to 200 fire detectors

Fallback interconnection

60 seconds to activate up to 50 fire detectors

Advanced automation for greater safety

While FireProtect 2 Jeweller detectors can be used as standalone devices, they gain many more capabilities within a larger Ajax system. They can interact with automation devices and MotionCam (PhOD) Jeweller detectors via scenarios, triggering automated responses to fire alarms. This interaction helps enhance home protection when people are away or speed up evacuation when they are on site.

To quickly assess the situation at the protected facility and respond accordingly.

Photo evidence of fire

Fire detected

FireProtect 2 Jeweller

MotionCam (PhOD) Jeweller

Cause of fire

To cut off power to a possible source of fire and protect appliances from the consequences of firefighting.

Power supply control

Fire detected

FireProtect 2 Jeweller

WallSwitch Jeweller

Mains power cut

Relay Jeweller

Emergency lights activated

To speed up people's evacuation and ease firefighters' access to the building.

Electric locks unlocking

Fire detected

FireProtect 2 Jeweller

Relay Jeweller

Emergency exits unlocked

Unique wireless technology

Unique wireless technology

Jeweller is Ajax’s proprietary radio protocol for secure two-way communication. It provides block encryption and device authentication during each communication session with an Ajax hub or radio signal range extender. Jeweller prevents sabotage, spoofing, and data theft.

Up to 5,550 ft of communication range in an open space

Data encryption

Notification of jamming and connection loss

Automatic power adjustment

Effortless installation and maintenance

FireProtect 2 (Heat/Smoke) Jeweller is ready to operate straight out of the box. With no enclosure disassembly required and intuitive in-app setup, it can be up and running within minutes. Maintenance and testing are just as effortless thanks to the self-test feature, real-time device state, and remote configuration available in Ajax apps.

Adding to the system via a QR code

Connection

SmartBracket panel with a 90° rotation angle and no enclosure disassembly

Installation

Configuration and testing in mobile and desktop Ajax apps

Setup

Dustproof and insect-resistant smoke chamber that does not require cleaning

Maintenance
1

Fallback interconnection is available only for FireProtect 2 Jeweller detectors with firmware version 5.59.2.9 or later.

Technical information

FireProtect 2 RB (Heat/Smoke) Jeweller

FireProtect 2 SB (Heat/Smoke) Jeweller

Ajax product categories

In an Ajax system, you can combine devices of all product categories: Intrusion protection, Video surveillance, Fire and life safety, or Comfort and automation. Create the system to suit your needs and manage it in a single interface.

Heat and smoke fire detectors

Protect your property from fires with advanced devices that detect the first signs of heat. Heat detectors give you additional peace of mind and can be used in areas where smoke detectors cannot.Heat detectors accurately detect and respond to convicted thermal energy, triggering an alarm to alert nearby occupants. They are designed to complement smoke detectors and are typically installed in areas where smoke detectors are unsuitable, such as kitchens, laundry rooms, or utility closets, where excessive dust or steam can trigger false alarms. Here are the most common types of heat detectors:Fixed temperature heat sensors are the most common type of heat detector found in homes and businesses. They sound an alarm when heat-sensitive alloys inside liquify in response to significant heat in the immediate area. Rate-of-rise thermal detectors signal an alarm when there's a rapid increase in heat, from 12 degrees to 15 degrees Fahrenheit, and utilize heat-sensitive thermocouples to measure temperature accurately.When it comes to smoke detectors, ionization smoke detectors have an electrical current that runs through two metal plates inside the device. They are ideal for detecting fires that spread quickly. Photoelectric smoke detectors go off when the light inside the device is disrupted by smoke, and detect small fires faster than an ionization smoke detector.Make sure your property is equipped with the proper detectors to keep your residents and assets safe. Familiarize yourself with the different types of detectors to ensure the best possible protection for your premises. Using the example of the Ajax combined fire detector, we will explain how such a device works and what its features are.

Heat and smoke detector Ajax FireProtect 2 (Heat/Smoke)

FireProtect 2 (Heat/Smoke) is a wireless smoke and temperature detector designed for instant fire detection. It features a unique smoke chamber that does not require cleaning, a dual-spectrum sensor that distinguishes smoke from steam, and thermistors that quickly react to burning synthetic materials. Its sophisticated software minimizes false alarms, and it meets the most modern fire safety standards.The device operates through steam, dust, and time and has a well-thought-out design, mounting, and in-app settings, which makes installation straightforward and quick.The smoke detection system uses optical sensors with infrared LEDs. The LEDs emit light with different wavelengths, which allows the detector to determine the size of the volatile particles and react only to smoke. The smoke chamber is protected from dust, dirt, and insects, and the optical system is designed so that non-volatile particles or insects cannot be in two beams simultaneously and cause a false alarm.FireProtect 2 (Heat/Smoke) also detects a rapid temperature rise with two built-in thermistors that are located outside the detector for faster threat detection. If the room temperature exceeds 64 °C or increases at more than 10 °C per minute, the detector recognizes this as a rapid temperature rise and raises the alarm. The temperature alarm can trigger even if there is no smoke in the room.

Connectivity: Jeweller communication technology and interconnected fire alarms

The device supports interconnected fire alarms and has an advanced algorithm that activates all fire alarm sirens within 20 seconds. The function is available only when the detectors work with the hub.Wireless alarm fire detectors FireProtect 2 (Heat/Smoke) can be used without connecting to an Ajax hub. In this case, the detector notifies fire alarms with a built-in siren and LED indication but does not send a notification to the user's smartphone, Ajax Translator, or PRO Desktop.The detector regularly checks the status of batteries and built-in sensors, and the hub notifies users and the monitoring station instantly if a malfunction is detected. The detector supports manual testing mode, which allows the installer to test the device at any time and to demonstrate to the customer the light and sound indication of the detector for various types of alarms.Wireless fire detector from Ajax FireProtect 2 (Heat/Smoke) features Jeweller communication technology, a radio protocol for fast and reliable two-way communication between hubs and connected devices. The protocol provides a wireless radio communication range with FireProtect 2 (Heat/Smoke) up to 1700 meters. This communication range allows you to install detectors even on large-scale objects.

Battery options: Replaceable and non-replaceable batteries

Two models of FireProtect 2 (Heat/Smoke) are available — with replaceable and sealed batteries. Detectors with replaceable batteries operate for up to 7 years with pre-installed CR123A batteries. After their discharge, the batteries can be replaced with new ones. The model with non-replaceable batteries works from built-in lithium batteries for at least 10 years. After the batteries are discharged, such a detector should be replaced with a new one.FireProtect 2 (Heat/Smoke) is a next-gen device that is perfect for homeowners, and large-scale facilities. Its accuracy through steam, dust, and time make it a reliable device that ensures the safety of everyone in the building.