LightSwitch (1-gang) [120] Jeweller

LightSwitch (1-gang) [120] Jeweller

Smart touch 1-gang light switch

FAQ

How long will it take the hub to detect a communication failure with a detector or device

By default, the hub is set to a hub–detector ping interval of 36 seconds and 30 undeliverable data packets to consider the device lost. With these settings, the hub will detect the loss of the detector in 18 minutes.

To reduce this time, go to the hub settings Settings-M in the Jeweller section and change the settings. The minimum time for detecting loss of connection with the device is 36 seconds (3 polls of 12 seconds each).

The time before raising the alarm by the communication loss between hub and device is calculated with the following formula:

Detector Ping Interval × Number of missed pings to determine connection failure

Note that with the minimum ping interval, short-term interference can lead to loss of connection with the device. Therefore, set the minimum values only if it is critically important to promptly inform about events in the system.

Connecting a bundled capacitor for LightSwitch [120]. Why is it needed, and how to connect it to lamps?

The bundled capacitor is a device intended to provide sufficient power supply for LightSwitch [120] and stable operation of lamps in the following cases:

  • the power of the lamp is less than 20 W (an approximate value that can vary depending on the type and technical characteristics of the lighting appliance);

  • the turned-off lamp is flashing;

  • LightSwitch [120] is malfunctioning or unstable;

  • adding LightSwitch [120] to the system fails (with an installed touch-sensitive panel);

  • another abnormal operation of LightSwitch [120] or lighting appliance is observed.

The bundled capacitor should be connected in parallel with the lighting device according to the following diagram: in a lamp socket or terminal board nearby.

In practice, the connection of a bundled capacitor to a lighting appliance can look as follows:

What scenarios are now available to me?

Currently, the following scenarios are available for Relay, WallSwitch and Socket:

In case of arming:

  • close the contacts (apply 230 V to the output)

  • to open contacts (stop feeding 230 V)

  • without action

In case of disarming:

  • close the contacts (apply 230 V to the output)

  • to open contacts (stop feeding 230 V)

  • without action

Actions during the arming/disarming are independent. Any other automation scenarios now are under development.