
FireProtect 2 RB (Heat/CO)
Wireless fire detector with temperature and CO sensors
The fire standard of the future
FireProtect 2 RB is a new generation detector for effective fire detection. Externally, the sensor has two thermistors that quickly detect temperature rise. A chemical sensor with a service life of at least 10 years will notify you of dangerous carbon monoxide concentrations. Elaborate software protects against false alarms, and also provides interconnected alarms of all fire detectors at the object in just 20 seconds. This is more than required by modern fire safety standards. The SmartBracket mounting panel, combined with in-app settings, provides simple and quick installation.

Up to 7 years of operation from replaceable batteries


Remote control and configuration
Up to 5500 ft
range of communication with an Ajax hub

Interconnected alarm in 20 seconds
85 dB built-in buzzer

SmartBracket
with adjustable rotation angle
Sensors

Ajax
Home: FireProtect 2: temperature exceeded the threshold value in the Kitchen

Ajax
Home: Photo by Scenario taken, MotionCam in the Kitchen
Informative in-app notifications
Two colours

Compliance
Hassle-free installation

Interconnected alarm in 20 seconds
85 dB built-in buzzer
Compliance
Hassle-free installation
FireProtect 2 in details
Fire alarm sensors: Ajax Systems Fire Detector
Fire detectors are tools for detecting a fire and preventing it from starting. The main mode of operation of the sensors provides for the registration of heat, smoke or gas in a protected area and sending notifications to the owner or to the control panel of the security company. There are several types of fire safety sensors, each with a unique target orientation and different detection methods:- Smoke detectors quickly detect sources of smoke. Such devices are equipped with a camera with an optical pair and an electrical signal processing unit inside the case. The sensor issues a fire alarm if the amount of smoke increases.
- Thermal sensors respond to fluctuations in ambient temperature. To improve fire safety, joint installation of smoke detectors is recommended, as such work increases the probability of fire detection and prevention. To reduce false positives, heat sensors are usually installed far from appliances that emit heat.
FireProtect 2 (Heat/CO) is a wireless fire detector with temperature and carbon monoxide sensors
FireProtect 2 is a new generation sensor for detecting fire. Two thermistors on the outside of the sensor allow it to immediately detect a rise in temperature.Sensor works autonomously thanks to two pre-installed CR123A type batteries.The wireless carbon monoxide and temperature sensor has a built-in alarm siren that notifies you of an event. The FireProtect 2 fire sensor can function both autonomously and with connection to the hub as part of the Ajax security system. The FireProtect 2 wireless fire detector is available in white and black colors, which allows you to adapt the device to any type of room interior. Once installed, the device can be detached and installed elsewhere using the mobility of the SmartBracket mount.
Features of the FireProtect 2 (Heat/CO) chemical fire detector
Synchronous alarm of all fire detectors installed in the room is triggered in 20 seconds with the sound of a siren and light notification. The alarm mode will be active until the cause of the trip is eliminated or until the user disables the alert.The wireless fire detector can work without connecting to the Ajax control panel or as part of the security system.When malfunctions are detected, the LED indicator on the device case signals this. For example, in case of battery discharge or end of service life. The wireless fire detector is tamper-proof. So, if there is an attempt to sabotage, remove from the mounting panel or damage the housing of the device, the user receives a warning in the Ajax application. The device also detects the loss of communication within 5 minutes at the initial settings. The time to detect a lost connection depends on the settings for the number of undelivered data packets. This information is specified in the Jeweller or Jeweller/Fibra settings. The polling period of the wireless fire detector can be adjusted from 12 to 300 seconds.
The principle of operation of the FireProtect 2 (Heat/CO) wireless fire detector
The FireProtect 2 fire sensor detects a rapid increase in temperature in the protected room. To quickly recognize threats, thermistors are located outside the sensor. The Ajax wireless fire detector detects and sounds an alarm if the room temperature exceeds 64°C or rises by 10°C or more within 1 minute. In FireProtect 2, a built-in chemical sensor with a service life of up to 10 years is responsible for detecting a harmful concentration of carbon monoxide. Carbon monoxide (CO) is a colorless, tasteless, and odorless gas produced when the fuel in heating engines and vehicle engines that use coal or other natural fuels does not burn completely. For example, it can be created through heating systems, boilers or fireplaces. In closed rooms with insufficient ventilation, life-threatening concentrations of carbon monoxide can accumulate. The synchronous fire alarm function activates the built-in sirens of all Ajax fire detectors in the system if at least one of them is activated. This allows as many people in the building as possible to be notified of the fire.The sirens of all FireProtect 2 sensors can be activated in 20 seconds thanks to the advanced algorithm of the synchronized alarm.