FireProtect 2 AC (Heat/Smoke) Jeweller
Wireless mains-powered fire detector with heat and smoke sensors
yA5lgs
9td1WlCommunication
Jeweller communication technology
Proprietary wireless communication technology to transmit commands, alarms, and events.
Key features:
- Two-way communication.
- Advanced anti-sabotage.
- Block encryption featuring a dynamic key.
- Instant notifications.
- Remote configuration in the Ajax apps.
Frequency bands
866.0 – 866.5 MHz
868.0 – 868.6 MHz
868.7 – 869.2 MHz
905.0 – 926.5 MHz
915.85 – 926.5 MHz
921.0 – 922.0 MHz
Depends on the region of sale.
Maximum effective radiated power (ERP)
up to 20 mW
Automatic power control to reduce power consumption and noise interference.
Radio signal modulation
GFSK
Radio communication range
up to 5,500 ft
Between detector and hub (or range extender) in an open space.
Encrypted communication
All stored and transmitted data are protected by block encryption featuring a dynamic key.
Frequency hopping
Radio communication uses frequency hopping to prevent interception and jamming.
Sensitive elements
smoke sensor
heat sensor
Smoke detection
Sensitive element
dual-spectrum optical sensor
Detects smoke by the size of particles in the air.
Protection from false alarms
Does not react to water vapor.
Patented smoke chamber
Protects the smoke sensor from dust, dirt, and insects.
Dangerous temperature detection
Sensitive element
according to the requirements for Class A1R heat detectors
Requirements of EN 54-5 and BS 5446-2 standards.
High temperature alarm
at temperatures above 147°F
Temperature spike alarm
when the temperature rises by more than 50°F in 1 minute or less
Additional features
Built-in siren
volume 85 dB at a distance of 9 ft
Sound notification of alarms. Remains active until the reason for triggering is eliminated or until the user manually disables the notification.
Interconnected fire detectors alarms
via primary interconnection
If one of the fire detectors in the system detects a threat, it sends an alarm to the hub. Within 20 seconds, the hub initiates an interconnected alarm and sends data to Ajax apps.
via fallback interconnection
At the same time with notifying the hub, the initiating detector sends an alarm directly to other detectors. All connected detectors activate the buzzer within a minute. It will work even in the worst-case scenario of losing connection with the hub.
LED indication
green is a power indication
An LED indicator on the device enclosure lights continuously when powered by an external power source. If the device draws power from the backup battery, the LED indicator lights up once every 56 seconds. This indication complies with the requirements stipulated in EN 14604 and EN 50291 standards.
yellow is a malfunction indication
An LED indicator on the device enclosure lights up to signal detected malfunctions. This can occur in instances such as battery depletion, smoke chamber contamination, or reaching the end of the service life.
red is a fire alarm indication
An LED indicator on the device enclosure lights up when the detector registers a fire alarm.
Button on the front panel of the detector
In normal mode, pressing the button initiates the smoke chamber test. In the event of an alarm or malfunction, pressing it turns off the detector sound notification.
External power supply
110–240 V~, 50/60 Hz
The phase and neutral cables from the external power supply should be connected to the WAGO terminals on SmartBracket mounting panel. To remove the detector from SmartBracket, there is no need to disconnect the power cables.
Recommendations
The device is designed for indoor installation only. SmartBracket mounting panel allows adjusting the position of the detector even after installation.
Sabotage protection
Tamper alarm
Notifications on attempts to detach the detector from the surface or remove it from the mounting panel.
Protection against spoofing
device authentication
Communication loss detection
within 15 minutes
The time required to detect a communication loss depends on the settings for the number of undelivered data packages (specified in the Jeweller or Jeweller/Fibra settings).
Power supply
Main
110–240 V~, 50/60 Hz
Up to 2 W of mains power consumption.
Backup
1 non-replaceable lithium battery CR-2/3AZ
Allows the detector to operate autonomously without the main power source.
Enclosure
Dimensions
4.80″ × 4.80″ × 2.13″
Weight
11.11 oz
Operating temperature range
from 32°F to 122°F
Operating humidity
up to 80%
Colours
Black
White
Complete set
FireProtect 2 AC (Heat/Smoke) Jeweller
SmartBracket mounting panel
WAGO 221 3-conductor terminal — 2 pcs.
(pre-installed in SmartBracket)
Installation kit
Quick start guide
hQt5e6
FireProtect 2 AC (Heat/Smoke) Jeweller
FireProtect 2 AC (Heat/Smoke) Jeweller
Construction Products Regulation (CPR)
Dedal Attestation & Certification LTD
EN 14604:2005/AC:2008
Radio Equipment Directive (RED)
Certificate issued by MiCOM Labs
- EN 300 220-1 V3.1.1
- EN 300 220-2 V3.2.1
Restriction of Hazardous Substances Directive (RoHS)
Shenzhen NTEK Testing Technology Co.
EN IEC 63000:2018
Electromagnetic Compatibility Directive (EMC)
Certificate issued by MiCOM Labs
- EN 301 489-1 V2.2.3
- EN 301 489-3 V2.1.1
- EN 55032:2015+A1:2020
- EN 55035:2017+A11:2020
- EN IEC 61000-3-2:2019+A1:2021
- EN 61000-3-3:2013+A2:2021
Low Voltage Directive (LVD)
Certificate issued by MiCOM Labs
- EN 62479:2010
- EN IEC 62368-1:2020+A11:2020
Australian/New Zealand Standard
SAI Global Pty Limited
- AS 3786:2014
FCC ID
Certificate issued by MiCOM Labs
2AX5VFIACHS1
IC ID
Certificate issued by MiCOM Labs
26860-FIACHS1
PSTI UK
Schedule 1
CableTrunk
Restriction of Hazardous Substances Directive (RoHS)
EN IEC 63000:2018