OBUbeD
Outlet [type F] Jeweller
Wireless smart wall outlet with power consumption monitor
yA5lgs
9td1WlComponents
Relay
OutletCore (smart) [ type F ] Jeweller
To control the power supply of the outlet.
Cover
All covers consist of two elements of the same color: the front panel and the receptacle cap.
SoloCover (smart) [ type F ]
It is used when the outlet is installed as a separate device.
SideCover (smart) [ type F ]
It is used when the outlet is installed on the right or left of the device set.
СenterCover (smart) [ type F ]
It is used when the outlet is installed between the device set.
Frames
Frames for two, three, four, and five Ajax outlets and switches in any combination.
Frame (2 seats)
Frame (3 seats)
Frame (4 seats)
Frame (5 seats)
Configuration
Single outlet
Outlet [ type F ] Jeweller is installed as a separate device.
Combined outlet
Outlet [ type F ] Jeweller is combined as a set with Ajax smart outlets and/or LightSwitch switches and installed into Frame side by side.
Cover colors
Black
RAL 9005
Graphite
RAL 7024
White
RAL 9003
Ivory
RAL 1013
Fog
RAL 7047
Oyster
RAL 9002
Grey
RAL 7004
Olive
RAL 7044
The RAL colors are as close as an approximation of the actual color. However, they may slightly differ, so please only use them as a guide to the color choice.
Communication
Jeweller communication technology
Proprietary wireless communication technology to transmit commands, alarms, and events.
Key features:
- Two-way communication.
- Advanced anti-sabotage.
- Block encryption featuring a dynamic key.
- Instant notifications.
- Remote configuration via the Ajax apps.
Frequency bands
866.0–866.5 MHz
868.0–868.6 MHz
868.7–869.2 MHz
905.0–926.5 MHz
915.85–926.5 MHz
921.0–922.0 MHz
Depends on the sales region.
Maximum effective radiated power (ERP)
up to 20 mW
Radio signal modulation
GFSK
Radio signal range
up to 3,600 ft
Between device and hub (or range extender) in an open space.
Encrypted communication
All the data stored and transmitted are protected by block encryption featuring a dynamic key.
Radio frequency hopping
Radio communication uses frequency hopping to prevent interception and jamming.
Key features
Control via smartphone
The user can set up the outlet configurations and receive a detailed event log in the Ajax app.
Automation scenarios
- security mode change reactions
- scheduled actions
- alarm reactions
- temperature scenarios
- humidity scenarios
- CO₂ level scenarios
- by pressing LightSwitch
Energy consumption monitor
Control of the current, voltage, power consumption, and electric energy consumed by connected appliances. All data is saved to the non-volatile memory and can be reset in the Ajax app.
Shutoff timer
Adjustable timer to turn off the connected appliances after the expired time: from 10 seconds to 2 hours.
Touch button
For manual control of the power supply to plugged-in devices. It can be enabled in the Ajax app.
LED indication
Informs about the outlet’s state and the power consumption of connected appliances with different colors. The brightness of the LED frame can be adjusted or turned off in the Ajax app.
Night backlight
Optional and can be turned off in the Ajax app device settings.
Operation modes
- pulse
- bistable
Contact state
normally open
Children protection
The outlet is equipped with special internal shutters. They protect children by preventing them from inserting items like screwdrivers, scissors, or hairpins into the outlet, and also guard against dust and splashes.
Service life
At least 150,000 switches.
Recommendations
The device is designed for indoor use only. A professional electrician should install the device.
Sabotage protection
Protection against spoofing
device authentication
Communication loss detection
after 36 s
Detection time depends on the Jeweller or Jeweller/Fibra settings.
Power supply
Power supply voltage
230 V~, 50 Hz
Average consumption
up to 1.5 W
Output power
up to 3 kW (resistive load at 230 V)
Current protection
1 A–16 A
Once the current exceeds the selected value, the outlet turns off automatically. The recommended value is 13 A for permanent load and 13–16 A for short-term load.
Voltage protection
min — 184 V~
max — 253 V~
Once the voltage exceeds the specified levels, the outlet turns off automatically.
Temperature protection
more than 203 °F
If protection is triggered, the outlet turns off.
Electric shock protection class
Class I (with grounding terminal)
Operating parameters
Operating temperature range
from 32 °F to 104 °F
Operating humidity
up to 75% with no condensation
Protection class
IP20
Dimensions
OutletCore (smart) [type F] Jeweller
2.85" × 2.99" × 1.75"
SoloCover (smart) [type F] Jeweller
front panel —3.24" × 3.24" × 0.4"
receptacle cap —1.67" × 0.85"
SideCover (smart) [type F] Jeweller
front panel —3.24" × 3" × 0.4"
receptacle cap —1.67" × 0.85"
СenterCover (smart) [type F] Jeweller
front panel —3.24" × 2.77" × 0.4"
receptacle cap —1.67" × 0.85"
Frames
Frame (2 seats) — 3.26" × 6.04" × 0.25"
Frame (3 seats) — 3.26" × 8.84" × 0.25"
Frame (4 seats) — 3.26" × 11.63" × 0.25"
Frame (5 seats) — 3.26" × 14.43" × 0.25"
Weight
OutletCore (smart) [type F] Jeweller
2.65 oz
SoloCover (smart) [type F]
front panel — 1.3 oz
receptacle cap — 0.28 oz
SideCover (smart) [type F]
front panel — 0.92 oz
receptacle cap — 0.28 oz
СenterCover (smart) [type F]
front panel — 0.88 oz
receptacle cap — 0.28 oz
Frames
Frame (2 seats) — 0.57 oz
Frame (3 seats) — 0.78 oz
Frame (4 seats) — 1 oz
Frame (5 seats) — 1.2 oz
Complete set
Outlet [ type F ] is a prefabricated smart outlet. All parts are purchased separately
hQt5e6
Outlet [type F] Jeweller
Outlet [type F] Jeweller
Radio Equipment Directive (RED)
Certificate issued by MiCOM Labs
- EN 300 220-1 V3.1.1
- EN 300 220-2 V3.2.1
Restriction of Hazardous Substances Directive (RoHS)
Test report issued by Shenzhen NTEK Testing Technology Co.
EN IEC 63000:2018
Electromagnetic Compatibility Directive (EMC)
Certificate issued by MiCOM Labs
- EN 301 489-1 V2.2.3
- EN 301 489-3 V2.1.1
- EN 55032:2015+A1:2020
- EN 55035:2017+A11:2020
- EN IEC 61000-3-2:2019+A1:2021
- EN 61000-3-3:2013+A2:2021
Low Voltage Directive (LVD)
Test report issued by Shenzhen NTEK Testing Technology Co.
- EN 62479:2010
- EN IEC 60669-2-1:2022 + A11:2022
- EN 60669-1:2018
- EN 60669-2-5:2016
Other technical safety requirements
Test report issued by Shenzhen NTEK Testing Technology Co.
IEC 60884-1:2022
PSTI UK
Schedule 1
Frame
Restriction of Hazardous Substances Directive (RoHS)
Test report issued by Shenzhen NTEK Testing Technology Co.
EN IEC 63000:2018