Language:
FireProtect 2 (Heat/Smoke/CO) Jeweller

FireProtect 2 (Heat/Smoke/CO) Jeweller

Wireless fire detector with heat, smoke, and CO sensors

Accuracy through steam, dust, and time

FireProtect 2 is a next-gen detector designed for residential fire safety. The unique smoke chamber does not require regular cleaning, the dual-spectrum sensor distinguishes smoke from steam, the thermistor quickly reacts to the synthetic materials burning, and sophisticated software minimizes false alarms. Thought-out design, mounting, and in-app settings make installation straightforward and quick. Everything meets the most modern fire safety standards.

FireProtect 2 features in a minute

Discover FireProtect 2

Interconnected alarm in 20 seconds

Interconnected alarm in 20 seconds

Versions with different battery type

Replaceable

Sealed

Sensors

Heat

Smoke

CO

Compliance

Remote control and configuration

Remote control and configuration

85 dB built-in siren

85 dB built-in siren

Informative in-app notifications

Ajax logo
10:00

Ajax

Home: Smoke detected, FireProtect 2 in kitchen.
Ajax logo
10:00

Ajax

Home: Photo by scenario taken, MotionCam in kitchen.

Jeweller radio communication

Jeweller radio communication

Power adjustment

Up to 5500 ft

range of communication with an Ajax hub

Operates as part of the Ajax system or without pairing with an Ajax hub

Two colours

Two colours
SmartBracket

SmartBracket

with an adjustable rotation angle

Hassle-free installation

1

QR code

2

SmartBracket

3

App

Dual-spectrum optical smoke sensor

Dual-spectrum optical smoke sensor

to filter false alarms

Dustproof smoke chamber impenetrable for insects

Dustproof smoke chamber impenetrable for insects

Compatible hubs and range extenders

Check

Wherever there is a risk of fire

Kitchen

Kitchen

Living room

Living room

Bedroom

Bedroom

Hall

Hall

Home office

Home office

Pantry

Pantry

Basement

Basement

Barn

Barn

Workshop

Workshop

Discover future-proof hardware

Future

 

Detection

Patented smoke chamber technology

Encouraged by world standards and best practices, Ajax reaches an entirely new level of technology in residential fire safety with FireProtect 2. A unique smoke chamber that is dustproof and impenetrable for insects, a dual-spectrum optical sensor, and a proprietary HazeFlow 2 software algorithm guarantee the speed and accuracy of fire detection — ultimate safety with no stress about false alarms.

Impenetrable for dust and insects

The smoke chamber is designed with zero possibility of contamination that can affect detection. A unique circulation mechanism provides the optical sensor with an unobstructed field to quickly identify products of combustion in the air.

The FireProtect 2 smoke chamber does not require regular cleaning.

Impenetrable for dust and insects

Ignores сooking fumes and water steam

The smoke chamber is hardwired with a dual-spectrum optical sensor that has blue and infrared LEDs with different wavelengths. It uses the most reliable real-time detection method, directly measuring the microparticle concentration in the air. This technology allows FireProtect 2 to determine the size of the volatile particles inside the chamber and respond only to smoke, ignoring vapour and water steam.

Ignores сooking fumes and water steam

Only real threats considered

In-depth research on materials combustion resulted in HazeFlow 2 — a smoke detection algorithm developed by Ajax. The algorithm contemporaneously analyses and compares data from the dual-spectrum optical sensor to a specified pattern to define smoke from vapour or steam. The detector instantly raises the alarm when pattern dynamics indicate a real case of fire.

Only real threats considered

Protects from invisible danger

Carbon monoxide (CO) is colorless, odorless, and otherwise imperceptible without a carbon monoxide detector, so poisoning can occur unnoticed. Even low concentrations can be enough to have a negative health impact, especially on those with chronic illnesses, pregnant, the elderly, and young children. High-level exposure can cause permanent damage or even death in a very short period of time. FireProtect 2 warns about a dangerous CO concentration at the level of 50 ppm before even the first signs of poisoning occur. A built-in chemical sensor is responsive to low concentrations and can accurately detect the CO level straight up to 10 years.

CO alarm

  • 50 ppm in no more than 90 minutes
  • 100 ppm in no more than 40 minutes
  • 300 ppm in no more than 3 minutes
CO alarm

Even when it's fire without smoke

FireProtect 2 is equipped with two class A1R thermistors to detect smokeless fire threats. They give a significant advantage in detecting a rapid temperature rise when synthetic materials burn, or a fire starts from smoldering. Thermistors are located outside the enclosure to eliminate life-saving detection delays. So FireProtect 2 is ready to detect a fire as fast as possible, even if it starts imperceptibly.

Heat alarm

  • 10°C increase in temperature within a minute
  • Exceeding +64°C
Heat alarm

Autonomous operation

Stable performance for a decade

Cutting-edge engineering of hardware and software allowed us to implement advanced capabilities and offer autonomy in the size of the compact smart detector. FireProtect 2 complies with strict residential fire safety standards with long-lasting battery life while featuring constant data exchange with a hub and real-time analysis system to filter false alarms. The detector is available in two versions with different battery options to cover every market need.

SB version

SB version

10 years of operation

with non-replaceable sealed batteries

RB version

RB version

Up to 7 years of operation

with replaceable CR123A batteries

Low battery warning

The detector reports low batteries at least 30 days before its full discharge. Installers and users get notifications from their Ajax apps. Also, FireProtect 2 has an LED indicator and audible beeps for a low battery alert.

In-app notification

Audible indication

LED indication

Alarm system

Always informed, everywhere

For residential fire alarm systems, informing people about fire danger is the priority. FireProtect 2 is equipped with a powerful 85 dB siren to eliminate the risk of missing an alarm. The detector uses impossible-to-ignore tones with different patterns to indicate an alarm or event, so it’s easy to recognize the type of threat and react accordingly.

Different sound and LED indications

Different sound and LED indications

  • Smoke or heat alarms

  • Dangerous CO level

  • Malfunction

  • Low battery level

  • End of life

Wireless interconnection

All FireProtect 2 detectors can synchronously notify about the fire. As soon as one of them detects a threat, it only takes 20 seconds for the sirens of other fire detectors at the facility to activate. If the fire occurs at night, the volume of 85 dB can wake up even a deep sleeper.

Wireless interconnection

Interconnected fire alarm in 20 seconds

Unleash the Ajax power

The Ajax smart and complex ecosystem brings new standards to the fire safety industry. FireProtect 2 is ready to protect your home without an Ajax hub but can do even more when connected to it. Intuitive Ajax apps provide remote setup and all detector information in real-time from anywhere the Internet is available, on a smartphone or PC. With instant notifications, there is no chance of missing a fire alert, and scenarios let you automate fire security to enhance home protection while you’re away. A complete set with stable wireless communication — essential reliability tested over the years by nearly two million users.

Only with Ajax

Full monitoring for the building

The system instantly notifies about alarms with the critical alerts from the Ajax apps. Security companies and users know exactly which device triggered, when and where it happened. The system controls each device state and reports if there is a malfunction or it's time to replace the batteries.

Data-rich notifications

The event log records 500 recent events within the system. The data is explicit with the device, time, and description of the event. It helps reconstruct the actual event and find the causes to obtain comprehensive information for firefighters or an insurance company.

Detailed event log

Monitoring with PRO Desktop

With PRO Desktop, building administration staff can observe not only security but Ajax fire detectors for instant reaction to alarms. Device statuses, event log, batteries data — the CMS operator has a complete picture in one intuitive interface, all informative and centralized. The installation engineer can remotely change the settings and provide services in time.

Monitoring with PRO Desktop

Advanced automation for greater safety

Ajax fire detectors are a part of the Ajax ecosystem and can interact with automation devices and PhOD detectors of the MotionCam lineup through scenarios. In the case of a fire alarm, the WallSwitch relay de-energizes the house, and Relay activates emergency lights. At the same time, MotionCam (PhOD) sends pictures into Ajax apps to identify the cause of the alarm. The result is a reliable combination of security and automation that works as a Swiss watch.

To find out the situation at the protected facility and quickly respond to it.

Photo evidence of fire
1

Fire detected

2

FireProtect 2

3

MotionCam (PhOD)

4

Cause of fire

To power off the possible cause of the fire and protect appliances from the consequences of firefighting.

Power supply control
1

Fire detected

2

FireProtect 2

3

WallSwitch

4

Mains power-off

5

Relay

6

Emergency lights on

To speed up people’s evacuation and ease firefighters' access to the building.

Electric locks unlocking
1

Fire detected

2

FireProtect 2

3

Relay

4

Emergency exits unlocked

Unique wireless technologies

The Ajax system uses two-way secure radio communication based on the Jeweller proprietary protocol. It supports block cipher encryption and device authentication on every session with the hub to prevent sabotage, spoofing, or data theft.

Ajax wireless technology has up to 1,700 meters of radio signal communication range in an open space, making it on average longer than competing solutions from different manufacturers. Automatic power adjustment makes it energy efficient by not using the maximum power of radio transmitters in system devices on a regular basis. It is also more stable, using less noisy radio frequencies. Ajax hubs use radio hopping to protect against radio interference and signal interception. The system automatically changes frequency within a band and notifies the security company and users about the jamming.

  • Up to 1,700 meters of radio communication with a hub

  • Encrypted two-way radio communication

  • Notifications about jamming and connection loss

Code
Jeweller

The Ajax radio protocol uses polling to display current device statuses and transmits alarms, events, and all the readings into the Ajax apps. Jeweller features encryption and authentication to prevent spoofing.

Learn more

Only with Ajax

Scaled and comprehensive

For complex radio signal conditions like large houses with thick walls or warehouses with several buildings, there is the ReX range extender. It boosts the range of all Ajax devices and manages their communication with the hub via Jeweller. And ReX 2 assures stable communication even through steel and concrete via Ethernet using the wire as the additional communication channel. Up to 5 range extenders can operate within one Ajax system to expand the network twice as big, covering underground parking, basements, and metal hangars.

  • Up to 5 range extenders within one system

  • Ethernet as an alternative communication channel

Effortless installation and maintenance

FireProtect 2 is ready to operate straight out of the box. There is no need to disassemble the detector during installation. With an improved SmartBracket panel, an installer can effortlessly fix the detector on ceilings and level it at 90° angles after mounting. The Ajax apps help quickly make the device a part of the system. And it can always be reconfigured remotely without site visits.

Equipped with unique dustproof technology, the maintenance-free smoke chamber does not require regular clean-ups. A self-test system automatically diagnoses sensors and reports their state to the hub. Testing can also be run manually anytime in the app or by pressing the detectors' front panel with any suitable item, either a hand or a mop handle.

Pairing with the security system via QR code

Connection

SmartBracket panel with an adjustable rotation angle — no need to disassemble the enclosure

Installation

Configuring and testing in mobile and desktop apps

Setup

A dustproof smoke chamber that does not require cleaning

Maintenance

Ajax product lines

Superior, Fibra, and Baseline product lines are mutually compatible. This opens up numerous possibilities for building systems of any configuration.

Fire sensors of the security system

Fire alarm system designed to detect fires, points in the room with high air temperature and smoke. These measures include an alarm system, fire suppression, smoke extraction, shut-off of supply ventilation and air conditioning to stop the spread of fire in the event of an emergency.

What are the components of a fire alarm system

Fire alarm systems include sensors, receiving and control equipment, warning systems, communication channels, backup power supply, special software and other elements.

Fire sensors are divided into four main types:

1) The heat sensor of the fire alarm system reacts to the presence of temperature changes. Heat sensors are divided into:
  • a) threshold - with a given limit of a certain temperature level, after which the sensors will be triggered.
  • b) integral — respond to a rapid temperature increase. Due to the temperature threshold at which the sensor is activated, which is approximately 70 °C, threshold fire sensors have relatively low efficiency. The low cost of these sensors is the only factor affecting demand. Fires at an early stage can be detected with the help of built-in fire detectors. However, due to the fact that they use two thermocouples, one outside the sensor and the other inside, and the signal processing system is built into the sensor itself, the cost of such fire detectors will be high.
Only when heat is the primary symptom of a fire can heat sensors be used for fire alarms. 2) Smoke detectors. Smoke in the air is detected by smoke detectors. The theory of scattering of infrared radiation on smoke particles is the basis of the operation of almost all types of smoke detectors. The disadvantage of such a sensor is that it can work in environments with high levels of steam or dust. Although it is obviously not used in dusty or smoky environments, the smoke detector is used quite often. 3) The flame sensor indicates the presence of an open fire or smoldering fireplace. Flame detectors must be installed in places where a fire can start without the prior release of smoke. Because flame detection occurs at an early stage, when conditions such as smoke and a significant increase of temperature are absent, they are more effective than the previous two types of detectors. In addition, in some industrial buildings, which are characterized by high dustiness or significant heat exchange, only fire detectors are used. 4) Combined fire alarm sensors combine different fire indication identification methods. Most often, combined sensors combine a heat detector with a smoke detector. This makes it possible to more accurately determine the presence of a fire indication so that an alarm signal can be sent to the remote control. The complexity of the technologies used to create these sensors affects their cost. A correctly constructed fire alarm system, which depends on the information from the fire detector, is directly responsible for the entire effectiveness of the fire extinguishing system. Thanks to this, you can evaluate the effectiveness of the fire protection system of the building as a whole, taking into account the optimal location, the use of the appropriate type of sensor for certain rooms and the quality of fire detectors. In the event of a fire, notification systems for residents, guests, or personnel of buildings and structures contribute to the prompt evacuation of people. Using the Ajax sensor as an example, we will show the principle of operation and features of combined fire sensors.

FireProtect 2 (Heat/Smoke/CO) — a wireless fire detector with smoke, temperature and carbon monoxide sensors

The FireProtect 2 (Heat/Smoke/CO) wireless fire detector is designed for quick fire detection. A dual-spectrum sensor can distinguish between smoke and water vapor. The thermistor quickly reacts to the burning of synthetic materials. The one-of-a-kind smoke chamber does not require frequent cleaning, and simple software reduces false alarms. All this complies with the latest fire safety regulations. The well-thought-out mounting and design of the sensor, as well as the settings via smartphone, ensure easy and quick installation of the fire sensor. A built-in siren for alarm and event notification is included in the fire detector. The FireProtect 2 (Heat/Smoke/CO) wireless fire detector can function both independently and as part of the Ajax security system.
The sensor is available in two versions. Model with replaceable batteries and non-replaceable - RB and SB, respectively.

The principle of operation of the Ajax FireProtect 2 (Heat/Smoke/CO) wireless fire detector

Detecting smoke and not ignoring water vapor with the fire detector Ajax FireProtect 2 is possible thanks to a bispectral optical sensor with blue and infrared LEDs. LEDs emit light with different wavelengths. This allows the device to determine the size of the volatile particles and react to the smoke. The smoke chamber of the sensor is protected from external debris and insects. Dust does not threaten detection and does not damage the device, even if it enters and settles in the smoke chamber. Air particles or insects cannot be in two beams at the same time and cause an alarm due to the structure of the optical system. Two built-in thermistors are responsible for the response to the increase in temperature of the wireless fire detector. Thermistors are located outside the sensor for better threat detection. The sensor detects rapid temperature rise and sounds an alarm if the room temperature exceeds 64 °C or rises by 10 °C or more within one minute, even in the absence of smoke. In FireProtect 2 (Heat/Smoke/CO), a built-in chemical sensor with a service life of at least 10 years is responsible for detecting a dangerous concentration of carbon monoxide. Carbon monoxide (CO) is a colorless, tasteless, and odorless gas produced when the fuel in heating engines and vehicle engines that use coal or other natural fuels does not burn completely. For example, it can be created through heating systems, boilers or fireplaces. In closed, sealed rooms with insufficient ventilation, life-threatening concentrations of carbon monoxide can accumulate. The  interconnected fire alarm fire alarm function activates the built-in sirens of all Ajax fire detectors in the system if at least one of them has responded to the trigger. This makes it possible to notify as many people as possible inside the building in the event of a fire.
The sirens of all FireProtect 2 (Heat/Smoke/CO) sensors can be activated in 20 seconds thanks to the advanced algorithm of the synchronized alarm.
FireProtect 2 (Heat/Smoke/CO) sensors can be used without connecting to an Ajax control panel. In this case, the sensor notifies of fire alarms with a built-in siren and LED indication, but does not send a notification to the user's smartphone, Ajax Translator or the PRO Desktop application.

Jeweller wireless communication technology

A radio protocol called Jeweller provides fast and reliable two-way communication between connected devices and the hub of the security system. The protocol allows wireless connection of the control panel with FireProtect 2 (Heat/Smoke/CO) at a distance of up to 1700 meters. Even on very large objects, sensors can be installed thanks to such a communication range. In a system with any number of FireProtect 2 (Heat/Smoke/CO), the radio protocol also allows for a synchronized alarm of fire detectors to be triggered in 20 seconds. Thanks to Jeweller, users and the monitoring panel can always view the current status of detectors in Ajax applications. The wireless fire detector Ajax FireProtect 2 (Heat/Smoke/CO) constantly checks the state of the battery and built-in sensors. If a fault is detected, the hub will immediately notify users and the monitoring console. And the sensor will turn on the built-in siren and LEDs for light and sound alarm notification, respectively. In Ajax applications, all sensor states can be checked at any time. The sensor can be tested manually. When you press the front panel of the sensor, it turns on. The mechanical button on the front panel can be pressed both by hand and, for example, with a mop. During the test, the built-in siren is activated, and the sensors are checked. This allows the installation engineer to test the device when necessary and show the customer how the sensor will react to different types of alarms with sound and light.

Autonomous operation of the FireProtect 2 (Heat/Smoke/CO) wireless fire detector

The FireProtect 2 (Heat, Smoke, CO) fire alarm sensor is available in two models with replaceable and fixed power cells. Sensors with replaceable batteries can last up to 7 years with CR123A batteries already installed. Discharged batteries can be replaced with new ones. The permanent battery model uses built-in lithium power cells for at least 10 years of operation. Such a sensor must be replaced with a new one after the batteries are discharged.

Installation and connection of the Ajax FireProtect 2 (Heat/Smoke/CO) wireless fire detector

It is not necessary to open the sensor enclosure to install FireProtect 2. Pre-installed replaceable or fixed power supplies are available, and no tools are required to remove the SmartBracket from the sensor. The SmartBracket mounting panel allows you to later align the position of the sensor after installation. In less than a minute, the sensor is connected to the Ajax security system. You need to run the Ajax app, scan the QR code and add the device to the security group and room.