Language:

Tech specs

Hub Hybrid (2G)

Control panel with Fibra, Jeweller and Wings support (2 × SIM 2G, Ethernet)

Hub Hybrid (2G)

Devices compatibility

Capacity

Ajax devices

up to 100
  • Wired and wireless devices in any proportion.
  • 5 range extenders max.
  • 10 sirens or keypads with a built-in siren max.

Cameras or DVRs

up to 25
  • RTSP support.
  • Seamless integration with the Dahua, Hikvision,
    Safire, EZVIZ, Uniview IP cameras and DVRs.

Users

up to 50
  • Any number of admin users within the limit.
  • PRO accounts for installers and monitoring companies.
  • Access management for regular users.

Automation scenarios

up to 32
  • Alarm reactions.
  • Scheduled actions.
  • Security mode changing reactions.
  • Temperature changing reactions.
  • Humidity changing reactions.
  • Reactions to changes in CO₂ concentration.
  • Reactions to pressing the Button.

Security groups

up to 9

Rooms

up to 50

Event log

up to 1000 events
Events are saved on the non-volatile onboard flash memory.

Wired communication

Fibra communication technology

Proprietary wired communication technology. Fibra combines the reliability of wires with the freedom of radio connection.
It features:
  • Two-way communication.
  • Advanced anti-sabotage.
  • Instant notifications.
  • Remote configuration via the Ajax apps.

Compatible wire

4–core cable
Bus connection.

Input

8 bus lines
Compatible with Fibra devices only.

Bus line length

up to 6.500 ft
When using the U/UTP cat.5 twisted pair.

Power supply of devices

up to 14.4 W
For all connected wired devices.

Output voltage range

19–24 V⎓

Topologies

  • Star
  • Ring
In the line breakage event, the ring splits into two working segments, the devices continue to operate, and the system notifies a security company and users about the incident.

Devices polling interval

from 12 to 300 s
Adjusted by PRO or user with admin rights in the Ajax app.

Encrypted communication

Wireless communication

Jeweller communication technology

Proprietary wireless communication technology to transmit alarms and events.
It features:
  • Two-way communication.
  • Advanced anti-sabotage.
  • Block encryption featuring a dynamic key.
  • nstant notifications.
  • Remote configuration via the Ajax apps.

Frequency bands

866.0 – 866.5 MHz
868.0 – 868.6 MHz
868.7 – 869.2 MHz
905.0 – 926.5 MHz
915.85 – 926.5 MHz
921.0 – 922.0 MHz
Depends on the region of sales.

Maximum effective radiated power (ERP)

up to 20 mW
Featured automatic power control to reduce power consumption and noise interference.

Radio signal modulation

GFSK

Radio signal range

up to 6.500 ft
Between the hub and connected devices (in an open space). Maximum range depends on the connected device.

Polling interval

from 12 to 300 s
Adjusted by PRO or user with admin rights in the Ajax app.

Encrypted communication

All the data stored and transmitted are protected by block encryption with a dynamic key.

Radio frequency hopping

Wings communication technology

Proprietary wireless communication technology to transmit photo verifications.
It features:
  • Two-way communication.
  • Block encryption featuring a dynamic key.
  • Advanced anti-sabotage.
  • Package re-uploading in case of transmission errors.
  • Photo delivery check.

Frequency bands

866.0 – 866.5 MHz
868.0 – 868.6 MHz
868.7 – 869.2 MHz
905.0 – 926.5 MHz
915.85 – 926.5 MHz
921.0 – 922.0 MHz
Depends on the region of sales.

Radio signal range

up to 5.600 ft
Between the hub and connected devices (in an open space). Maximum range depends on the connected device.

Radio frequency hopping

Radio communication uses frequency hopping to prevent interception and jamming.

Recommendations

110–240 V~ power supply. For indoor use only.

Communication channels

Ethernet

1 × 8P8C socket
Up to 100 Mbps.

Cellular

2 × micro–SIM slot

Cellular bands

2G
(GSM900/DCS1800 (B3/B8))

Automatic switching between communication channels

  • Switching between SIMs — up to 4 minutes.
  • Switching between Ethernet and SIM — instantly.

Communication channels prioritization

1. Ethernet
2. Cellular connection
Communication channels work in parallel to increase system reliability. Most of the data is transmitted via Ethernet.

Alarm Transmission System Categories

SP2, SP5, DP3

Control panel operation method

Pass-through

Signaling security

S2
Substitution security.

Information security

I2

Notifications

Supported notification types

  • Push
  • SMS
  • Calls

Event types

  • Alarms
  • Malfunctions
  • Events
  • Security mode changing
The notification types are configured individually for each user. Notifications could be customized for A–D schemes according to EN 50131 requirements.

Photo verification

Photo verification types

  • Photo by alarm
  • Photo by scenario
  • Photo on demand
  • Photo by schedule
The Photo by Schedule feature is available for hubs with firmware version OS Malevich 2.19 or higher.

Photo delivery time

up to 9 s
by default.

Photo resolution

up to 640 × 480 pixels
Depends on the detector.

Number of photos in a series:

from 1 to 5 pictures

Monitoring

Supported protocols

  • SurGard (Contact ID)
  • SIA (DC-09)
  • Other proprietary protocols

Event types

  • System alarms and events
  • Photo verifications
  • Panic button coordinates

Power supply

Main power supply type

Type A

Device operating AC voltage range

110–240 V~, 50/60 Hz
From the main power supply. Up to 10 W of mains power consumption.

Device operating DC voltage range

10.5–15 V⎓
From the backup battery (not included). Hub has space in the enclosure and rails for installing batteries with a capacity of 4, 7, or 9 Ah.

Autonomous operation

up to 60 hours
Hub Hybrid with a 7 Ah backup battery can power a system of 30 wired devices for 60 hours. Wireless devices operate on batteries and do not require additional power supply.

Low battery voltage

11.7 V⎓

Low battery recovery voltage

12.6 V⎓

End of life battery voltage

10.5 V⎓
Hub Hybrid is switched off.

Maximum output peak-to-peak ripple battery voltage

220 mV⎓

Minimum backup battery energy level in the charged state

100 %

Current consumption

Maximum rated output

0.6 A

Maximum at nominal voltage

105 mA

Quiescent at nominal voltage

95 mA

Average*

up to 90 mA
When GSM and Ethernet are enabled.
up to 50 mA
When Ethernet is disabled.
* From the backup battery after the loss of the main power supply.

Casing

Dimensions

7.56″ × 9.37″ × 3.94″

Weight

30.05 oz

Operating temperature range

from 14°F to 104°F

Operating humidity

up to 75%

Protection class

IP30

Colours

Black
White

Complete set

Hub Hybrid (2G)
Power cable
Screw terminal block Adapter (only for INCERT compliance)
Battery connection cable
Ethernet cable
Casing
Installation kit
Eight 120 Ω termination resistors
Quick start guide

Additional information

Compliance with standards

Warranty

24 months

Distinctions from other hubs

User manual