FireProtect 2 RB (Heat/Smoke/CO) UL Jeweller

Wireless combined heat, smoke, and CO detector with replaceable batteries

FireProtect 2 RB (Heat/Smoke/CO) UL Jeweller

yA5lgs

9td1Wl

Communication

Jeweller communication technology

Proprietary wireless technology for alarm and event transmission.

Key features:

  • Two-way communication.
  • Protection against device spoofing.
  • Block encryption featuring a dynamic key.
  • Instant notifications.
  • Remote control and configuration in Ajax apps.

Frequency band

905.0–926.5 MHz

Certified by UL/ULC standards.

Maximum effective radiated power (ERP)

up to 20 mW

Automatic power control to reduce power consumption and radio interference.

Radio signal modulation

GFSK

Radio signal range

up to 5,550 ft

Between the detector and a hub (or range extender) in an open space.

Encrypted communication

All stored and transmitted data are protected by block encryption featuring a dynamic key.

Frequency hopping

To prevent radio interference and jamming.

Sensitive elements

smoke sensor

heat sensor

CO (carbon monoxide) sensor

Smoke detection

Sensitive element

double-spectrum optical sensor

Detects smoke by the size of particles in the air.

Patented smoke chamber

Protects the smoke sensor from dust, dirt, and insects.

Dangerous temperature detection

Sensitive element

for low temperature detectors

Requirements of UL 521.

High temperature alarm

at temperatures above 135 °F

Carbon monoxide (CO) detection

Sensitive element

chemical CO sensor

Alarm for exceeding CO level

70 ppm (0.007%) — in 60–240 minutes
150 ppm (0.015%) — in 10–50 minutes
400 ppm (0.04%) — in 4–15 minutes

CO concentration of 400 ppm (0.04%) within 3 hours can be life-threatening. The detector stops notifying about the dangerous level of carbon monoxide when the concentration drops to 70 ppm (0.007%) within 1 minute.

Sensor service life

10 years

After 10 years of operation, the detector must be replaced with a new one.

Additional features

Built-in siren

85 dB volume at a distance of 9 ft

Sound notification of alarms. Active until the reason for triggering is eliminated or until the user disables notification.

Interconnected Fire Detectors Alarm

All fire detectors in the system turn on built-in sirens if at least one detector registers an alarm. An interconnected fire alarm is activated within one “hub — detector” polling interval but no more than 20 seconds later.

LED indication

yellow indicates malfunctions

An LED indicator on the device enclosure lights up when malfunctions are detected, such as discharged batteries, contamination of the smoke chamber, or end of the service life.

red indicates fire alarms

An LED indicator on the device enclosure lights up when the detector registers a fire alarm.

Button on the front panel of the detector

In normal mode, pressing the button starts the smoke chamber test. In the case of an alarm or malfunction, pressing the button turns off the detector sound notification.

Recommendations

The device is designed for indoor installation only. SmartBracket mounting panel enables adjusting the position of the detector after installation.

Sabotage protection

Tamper alarm

Alerts of attempts to detach the detector from the surface or remove it from the mounting panel.

Protection against spoofing

device authentication

Communication loss detection

after 36 s

Detection time depends on the Jeweller or Jeweller/Fibra settings and can’t exceed 200 s.

Power supply

Batteries

2 × CR123A (pre-installed)

3 V⎓, 1,600 mAh

Manufacturer: Ajax Systems

Up to 5 years of battery life.

Enclosure

Dimensions

4.88″ × 4.88″ × 1.77″

Weight

9.68 oz

Operating temperature range

from 32°F to 100.4 °F

Certified by UL/ULC standards.

Operating humidity

up to 80%

Protection class

IP20

ttx
ttx

Colours

Black

White

Complete set

FireProtect 2 RB (Heat/Smoke/CO) UL Jeweller

SmartBracket mounting panel

Installation kit

2 × CR123A battery (pre-installed)

Quick start guide

hQt5e6

FireProtect 2 RB (Heat/Smoke/CO) UL Jeweller

FireProtect 2 RB (Heat/Smoke/CO) UL Jeweller

FCC ID

Certification Issued Under the Authority of the Federal Communications Commission

2AX5VFISMHTCJ1UL

IC ID

Certificate issued by MiCOM Labs

26860-FISMHTCJ1UL

CSA

Certificate issued by CSA Group Testing & Certification Inc.

ANSI/UL 62368-1 Ed. 3

CSA C22.2 No. 62368-1:19 Ed. 3

Standard for Safety Smoke Detectors for Fire Alarm Systems

Certificate issued by Intertek Group plc.

UL 268:2023 Ed.8

CAN/ULC S529:2023 Ed.5

Standard for Safety Gas and Vapor Detectors and Sensors for Fire Alarm Systems

Certificate issued by Intertek Group plc.

UL 2075:2013 Ed.2+R:04Aug2023

CAN/ULC S588:2017 Ed.1+R1