Tech specs
Socket (type F) Jeweller
Wireless smart plug with a power consumption monitor
Devices compatibility
CheckPower supply
Power supply voltage
110–230 V~, 50/60 Hz
Maximum continuous load current
11 A
Output power
up to 2.5 kW (resistive load at 230 V~)
up to 1.2 kW (resistive load at 110 V~)
Average consumption
up to 1 W
Current protection
more than 11 A (when Current protection is enabled)
more than 13 A (when Current protection is disabled)
Once the current exceeds the specified level, the plug turns off automatically.
Voltage protection for 230 V~ mains electricity
min — 184 V~
max — 253 V~
Once the voltage exceeds the specified levels, the plug turns off automatically.
Voltage protection for 110 V~ mains electricity
min — 88 V~
max — 121 V~
Once the voltage exceeds the specified levels, the plug turns off automatically.
Temperature protection
more than 185 °F
If protection is triggered, the plug turns off.
Electric shock protection class
Class I (with grounding terminal)
Communication
Jeweller communication technology
Proprietary wireless communication technology to transmit commands, alarms, and events.
Key features:
- Two-way communication.
- Advanced anti-sabotage.
- Block encryption featuring a dynamic key.
- Instant notifications.
- Remote control and configuration in Ajax apps.
Frequency bands
866.0–866.5 MHz
868.0–868.6 MHz
868.7–869.2 MHz
905.0–926.5 MHz
915.85–926.5 MHz
921.0–922.0 MHz
Depends on the sales region.
Maximum effective radiated power (ERP)
up to 25 mW
Radio signal modulation
GFSK
Radio communication range
up to 3,300 ft
Between the device and a hub (or a range extender) in an open space.
Encrypted communication
All stored and transmitted data are protected by block encryption featuring a dynamic key.
Frequency hopping
To prevent radio interference and jamming.
Key features
Control via smartphone
The user can set up the plug configurations and receive a detailed event log in the Ajax app.
Automation scenarios
- By arming/disarming
- By schedule
- By alarm
- By temperature
- By humidity1
- By CO2 concentration1
- By touching LightSwitch / pressing Button
1 Scenarios by humidity and CO2 concentrations are available when LifeQuality Jeweller is added to the system.
Energy consumption monitor
Control of the current, voltage, power, and electric energy consumed by connected appliances.
Adjustable pulse duration2
from 1 to 255 s
LED indication
Informs about the plug’s state and the power consumption of connected appliances with different colors. The brightness of the LED frame can be adjusted or turned off in the Ajax app.
Operation modes
- pulse2
- bistable
2 Available on devices with firmware version 5.54.1.0 or higher manufactured after March 4, 2020.
Contact state
- normally open
- normally closed
Childproofing
The plug is equipped with special internal shutters. They protect children by preventing them from inserting items like screwdrivers, scissors, or hairpins into the plug and also guard against dust and splashes.
Recommendations
The device is designed for indoor use only. A professional electrician should install the device.
Sabotage protection
Protection against spoofing
device authentication
Communication loss detection
after 36 s
Detection time depends on the Jeweller or Jeweller/Fibra settings.
Enclosure
Dimensions
1.77" × 1.77" × 2.58"
Weight
2.05 oz
Operating temperature range
from 32 °F to 104 °F
Operating humidity
up to 75% with no condensation
Protection class
IP20
Colors
Black
White
Complete set
Socket (type F) Jeweller
Quick start guide
Certification and compliance with standards
Socket (type F) Jeweller
Socket (type F) Jeweller
Radio Equipment Directive (RED)
Certificate issued by MiCOM Labs
EN 300 220-1 V3.1.1
EN 300 220-2 V3.2.1
Restriction of Hazardous Substances Directive (RoHS)
Test report issued by Shenzhen NTEK Testing Technology Co.
EN IEC 63000:2018
Electromagnetic Compatibility Directive (EMC)
Certificate issued by MiCOM Labs
EN 301 489-1 V2.2.3
EN 301 489-3 V2.1.1
Low Voltage Directive (LVD)
Certificate issued by MiCOM Labs
EN 62479:2010
EN 60730-2-7:2010 in conjunction with IEC 60730-1:2011
PSTI UK
Schedule 1