Supported connection types:
Designation | Type | Note |
NO | Normally open. | |
NC | Normally closed, without resistors. | |
EOL (NC with resistors) | Normally closed, with one resistor. There are 3 states: OK, alert and shorted out. | |
EOL (NO with resistors) | Normally open, with one resistor. There are 3 states: OK, alert and contacts damaged. | |
2EOL (NC with resistors) | Normally closed, with 2 resistors. There are 4 states: OK, alert, tamper alarm and shorted out. | Available for MultiTransmitter with firmware version 2.13 and higher. MultiTransmitter must be connected to Hub Plus, Hub 2, Hub 2 Plus, or Superior Hub Hybrid. The Hub model does not support this type of connection. |
2EOL (NO with resistors) | Normally open, with 2 resistors. There are 4 states: OK, alert, tamper alarm and contacts damaged. | Available for MultiTransmitter with firmware version 2.13 and higher. MultiTransmitter must be connected to Hub Plus, Hub 2, Hub 2 Plus, or Superior Hub Hybrid. The Hub model does not support this type of connection. |
3EOL (NC with resistors) | Normally closed, with 3 resistors. There are 5 states: OK, alert, tamper alarm, malfunction and shorted out. | Available for MultiTransmitter with firmware version 2.13 and higher. MultiTransmitter must be connected to Hub Plus, Hub 2, Hub 2 Plus, or Superior Hub Hybrid. The Hub model does not support this type of connection. |
3EOL (NO with resistors) | Normally open, with 3 resistors. There are 5 states: OK, alert, tamper alarm, malfunction and contacts damaged. | Available for MultiTransmitter with firmware version 2.13 and higher. MultiTransmitter must be connected to Hub Plus, Hub 2, Hub 2 Plus, or Superior Hub Hybrid. The Hub model does not support this type of connection. |
Supported detector types:
Pulse
Bistable