Socket Plus (type G) Jeweller
Smart plug with protection against sparks and electric arc
Compatibility
Compatible hub models
Compatible range extenders
Communication
Jeweller communication technology
Proprietary wireless technology for transmission of events.
- Two-way communication.
- Advanced anti-sabotage.
- Block encryption featuring a dynamic key.
- Instant notifications.
- Remote configuration via the Ajax apps.
Frequency bands
868.0 – 868.6 MHz
868.7 – 869.2 MHz
905.0 – 926.5 MHz
915.85 – 926.5 MHz
921.0 – 922.0 MHz
Depends on the sales region.
Maximum effective radiated power (ERP)
up to 20 mW
Automatic power control to reduce power consumption and radio interference.
Radio signal modulation
GFSK
Radio communication range
up to 3,600 ft
Between plug and hub or range extender in an open space.
Radio signal encryption
All the data stored and transmitted are protected by block encryption with a dynamic key.
Radio frequency hopping
Radio communication uses frequency hopping to prevent interception and jamming.
Actuating element
Electromagnetic relay
Closes and opens the electric circuit. Designed for more than 200,000 switches.
Energy consumption parameter check
Energy consumption monitoring
- voltage
- load current
- power consumption
- energy consumed
Maximum current protection
1–16 A
Load current
up to 13 A (up to 5 seconds)
Current protection (constant load)
3 A — fluorescent lamps
8 A — incandescent lamps
13 A — general inductive loads
Additional features
Spark and arc protection
triggers if an arc occurs in a device or conductor connected to the socket
Operation modes
pulse
bistable
Adjustable pulse duration
1 to 255 s
Set up in Ajax apps. The setting is available when the socket operates in pulse mode.
LED indication
Temperature protection
203 °F
The socket turns off automatically if the temperature is exceeded.
Contact state
normally open (NO)
normally closed (NC)
Set up in the socket settings. Can be set for both pulse and bistable operation modes.
Scenarios
- by alarm
- reaction to security mode change
- scheduled actions
- by pressing Button
- by temperature
- by humidity
- by CO2 concentration
- by pressing LightSwitch
Recommendations
Anti-sabotage protection
Protection against forgery
device authentication
Communication loss detection
from 36 s
Power supply
Power supply voltage
230 V~ ± 10%
50 Hz
Output power
up to 3 kW
Average power consumption of the device
≤ 1.5 W
Overvoltage protection
minimum — 184 V~
maximum — 253 V~
Electric shock protection class
class I
With grounding terminal.
Enclosure
Dimensions
2.1″ × 2.1″ × 2.2″
Weight
3.1 oz
Operating temperature range
from +32 °F to +104 °F
Operating humidity
up to 75%
Protection class
IP20
Colours
Black
White
Complete set
Socket Plus (type G) Jeweller
Quick Start Guide