How to directly connect the hub to the CMS via SIA DC-09 protocol

Updated

How to directly connect the hub to the CMS via SIA DC-09 protocol

The Ajax system can be connected to the Central Monitoring Station (CMS) via Ajax Cloud, Ajax Translator PRO plugin, Ajax Translator app, or SIA DC-09 protocol. This article guides you through the process of directly connecting the hub to the CMS via SIA DC-09 protocol.

SIA DC-09 is a protocol for communication with the CMS, supporting enhanced protection for transmitted messages with 128-bit encryption. Check the documentation for a complete list of commands and a protocol description.

When using SIA DC-09 protocol, all hub events are sent directly to the monitoring station, bypassing the Ajax Cloud server. In this case, Ajax Translator PRO or Ajax Translator is also not required.

How to configure a direct connection via SIA DC-09 protocol

On the CMS

Configure the reception of hub events on the CMS. If you intend to use encryption, specify its key. The encryption key may contain up to 32 HEX or 16 ASCII characters.

In the Ajax app

An admin or a PRO with the rights to configure the system settings can directly connect the hub to the CMS in any Ajax app.

Types of accounts and their rights

To set up a direct connection, select the space and go to its settings by pressing the gear icon Settings-MSecurity companiesMonitoring station:

  1. In the Protocol field, select SIA DC-09 (SIA-DCS).

  2. If necessary, deactivate certain channels for sending alarms to the CMS. All channels are activated by default: Ethernet, Cellular, and Wi-Fi (if available).

  3. Specify the primary and secondary IP addresses of the CMS for event transmission.

  4. Configure the Monitoring station periodic test interval option (disabled by default) from 1 minute to 24 hours to check the hub’s connection to the CMS. If the connection is lost, the hub stops sending periodic test reports.

  5. Select whether the hub maintains a constant connection to the CMS or connects only on demand. The Connect on demand feature is disabled by default, and the hub maintains a continuous connection to the CMS.

  6. In the Object number field, enter the hub number.

  7. Enable Encryption and use the same key as on the CMS for transmitting hub events in an encrypted format (using AES-128 encryption).

  8. If necessary, activate the Send coordinates feature.

  9. If necessary, adjust settings in the Alarm restoration on ARC menu.

How to stop monitoring of the facility

If you need to suspend the receipt of events by the Ajax hub, disable all communication channels in the space settings (Control ControlFilledBlack-M tab → Settings Settings-MSecurity companiesMonitoring station).

Popular CMSs that support SIA DC-09

  • Patriot Alarm

  • SIMS

  • ABsistemDCNGv2

  • TCR3000

  • Gemini Alarm Monitoring Software

  • Horus

  • Immix

  • MVS-NET

  • Safecon

  • SMS

  • Stages

  • URMET

  • V1 and F1

  • WBB

  • eLipse

  • AM/Win system

  • LISA

  • Sabanet s.r.l.