Fully autonomous fire detectors

The Ajax security system's fire barrier is wireless fire detectors that instantly alert about smoke detection or rapid temperature rise. A combined fire and carbon monoxide detector saves from CO poisoning, which is deadly.

As part of the Ajax security system, fire detectors alert users via connected sirens, mobile app, SMS, or call. Multiple detectors connected to the hub can activate an alarm synchronously if at least one of them is triggered. The interconnected alarm significantly increases the chance that everybody in a premise will be notified about the fire timely.

Having two batteries and a built-in buzzer, Ajax fire detectors are always ready to report about danger, regardless of power supply or control panel connection.

FireProtect

Wireless fire detector
Photoelectric sensor for smoke detection
Temperature sensor for fire detection
Built-in siren for 85 dB alerts
Can work without the hub
Up to 4 years of operation from battery
Communication with the hub at a distance of up to 1,300 m

FireProtect Plus

Wireless fire detector with carbon monoxide sensor
Photoelectric sensor for smoke detection
Temperature sensor for fire detection
CO sensor detecting 0,005% concentration of carbon monoxide
Built-in siren for 85 dB alerts
Can work without the hub
Up to 4 years of operation from battery
Communication with the hub at a distance of up to 1,300 m

Features of Ajax fire detectors

2 in 1

Ajax fire detectors combine smoke and temperature sensors. They eliminate the situation when the security system does not detect a smokeless fire. The built-in temperature sensor triggers when the maximum temperature reaches +60°C and when a premise temperature rises by 30°C in 30 minutes or faster.

Controlling own operability

Ajax fire detectors notify in advance of the need to replace the batteries and clean the smoke chamber from dust. Notifications come in the Ajax app or SMS. Replacing the batteries and cleaning the smoke chamber does not require special skills and takes minutes.

Meeting European standards

FireProtect and FireProtect Plus combine different sensors and protect against false alarms according to strict fire prevention requirements. The detectors are certified to EN 14604, which confirms their effectiveness in various conditions. Even in a changing environment, fire detectors won't bother users with false alarms: HazeFlow digital algorithm double-checks smoke before activating an alarm.

Using reliable communication technology

Fire detectors and hubs communicate via the Jeweller radio protocol. It is a TDMA technology with strong encryption. In the event of radio interference or jamming attempt, Ajax switches the radio frequency, notifying users and a security company of the situation.

Fire sensors in the security system

Security system fire detectors are devices that detect the signs of a fire starting in a guarded room. Several fire sensors are installed at the facilities, which monitor the temperature rise or the appearance of smoke. All sensors of this type are connected to the same network, which activates fire extinguishing systems, informs users of the security system about the incident, informs the security company or fire department, or all of these actions.

Types of fire detectors

Security alarm fire detectors are autonomous — they operate from an independent power source, often equipped with their own siren, which reports a fire alarm with sound or light.

The second type of fire sensors provides for their use as part of a security system. The sensors are connected to the alarm control panel, which, after an alarm, turns on the sirens and informs users about the incident.

Fire sensors by type of operation are of the following types:

Smoke detector fire

This type of fire detector is equipped with a small chamber through which room air passes. Infrared radiation is supplied inside, and a light-sensitive sensor is located at the exit. When smoke passes through the chamber, infrared rays are reflected from it and hit the sensor. The smoke sensor analyzes the data and responds to deviations from the norm. With this reaction to a fire, it can be identified in the early stages, since smoke can be released for several hours.

Sensors with a reaction to changes in air temperature

The principle of operation of such a fire detector is based on the optical analysis of thermal radiation. Such devices, using IR cameras, analyze thermal radiation and detect an excess of the norm, after which they inform users about the incident.

Fire detectors for the security system from Ajax

For fire safety in a guarded room, Ajax offers wireless, addressable sensors that raise an alarm when a sudden increase in temperature or smoke is detected. Also, you can use a fire detector with an additional CO-sensor in order to detect a carbon monoxide leak in time.

The principle of operation of Ajax fire detectors

Fire detection sensors from Ajax combine a thermal sensor and a smoke detection sensor. In this way, the user will avoid situations where the fire system ignores a fire without smoke. The thermal sensor of the sensor will work if the temperature limit reaches +60°С and if the room temperature rises by 30°С in 30 minutes or less.

Fire detectors as part of the Ajax alarm system will always report a danger, regardless of the presence of power or communication with the alarm control panel, thanks to two pre-installed batteries and built-in sirens.

Fire detectors of the Ajax security system inform system owners about the incident by messages in the mobile application, calls, SMS messages and sirens at the scene.

Several fire detectors connected to the control panel will raise a synchronous alarm if at least one device is triggered. Thus, all those present in the building learn about the fire in time.

The Ajax security system can be connected to the central monitoring station of a security company. Then, in the event of a fire alarm, a rapid response team will be sent to the facility to check and eliminate the incident.

Ajax fire detectors

The line of fire detection sensors from Ajax includes the following sensors:

  1. FireProtect is a wireless fire detector with a temperature sensor. The device will detect smoke with a photoelectric sensor, and fire with a thermal sensor. The fire detector can work without connection to the alarm central and has a built-in siren.
  2. FireProtect Plus is a wireless fire detector, additionally equipped with a carbon monoxide sensor with a built-in siren and the possibility of autonomous operation.

Features of Ajax fire detectors

Ajax fire detectors have the following features:

  • Secure communication

Fire detectors from Ajax transmit information to the control panel of the security system via the Jeweler two-way radio protocol. This technology protects the transmitted data with strong encryption. If there is interference on the radio or an attempt is made to jam the connection, Ajax changes the radio frequency and notifies system users and the security company about the incident.

Learn more about Jeweler radio technology

  • Compliance

The FireProtect and FireProtect Plus fire detectors are equipped with different sensors for superior performance. Also, the devices are protected from false alarms in accordance with fire safety requirements. The sensors are certified, which confirms their effectiveness in various conditions. The HazeFlow digital algorithm checks for smoke before an alarm is triggered.

  • Health monitoring

The user of Ajax fire detectors will know in advance about the need to replace the batteries. The sensors also indicate the need to clean the smoke chamber from dust with an audible signal. The owner of the security system will receive an additional notification in the form of SMS and in the Ajax application.

Spelling error report

The following text will be sent to our editors: