Ajax Superior DoorProtect Flush (3EOL) user manual

Updated

Ajax Superior DoorProtect Flush (3EOL) is a wired 3EOL opening detector with anti-sabotage features. The device is available in two versions: Ajax Superior DoorProtect Flush (3EOL) for concealed mounting and Ajax Superior DoorProtect Flush (3EOL) with Surface-mount kit for either concealed or surface mounting. Surface-mount kit can be purchased separately.

Ajax Superior DoorProtect Flush (3EOL) is a device of the Superior product line. Only accredited Ajax Systems partners can sell, install, and maintain Superior products.

Functional elements

Ajax Superior DoorProtect Flush (3EOL)

Functional elements
Functional elements
  1. Cable.
  2. Detector.
  3. Detector flush-mount enclosure.
  4. Holes for securing the flush-mount enclosure to a surface.
  5. Magnet flush-mount enclosure for installing on a ferromagnetic surface.
  6. Magnet flush-mount enclosure for installing on a non-ferromagnetic surface.
  7. Neodymium magnet.

Surface-mount kit

Surface-mount kit
Surface-mount kit
Surface-mount kit
Surface-mount kit
Surface-mount kit
Surface-mount kit
  1. Detector surface-mount enclosure.
  2. Magnet surface-mount enclosure.
  3. Recesses for aligning the spacers with surface-mount enclosures.
  4. Holes for securing the surface-mount enclosures to a surface.
  5. Latches for securing the surface-mount covers to the mounting panels.
  6. Detector mounting panel.
  7. Place for installing the detector.
  8. Magnet mounting panel.
  9. Place for installing the magnet.
  10. Recesses for cutting holes to route the cable from the side of the surface-mount enclosure. Recesses are provided on each side.
  11. Spacer 0.08″ — 4 pcs (included in the complete set).
  12. Spacer 0.24″ — 1 pc (included in the complete set).

Compatible integration modules

Ajax Superior DoorProtect Flush (3EOL) requires an integration module that supports 3EOL connections. The detector can be connected to an Ajax integration module or a third-party integration module if the detector is not used in an Ajax system.

Operating principle

Ajax Superior DoorProtect Flush (3EOL) consists of two parts: a detector with two reed switches and a neodymium magnet required to detect opening. The first reed switch detects door or window opening and closing events, while the second reed switch detects magnetic masking attempts.

The opening reed switch changes its contact state when the magnet approaches or moves away from it, while the magnetic masking reed switch changes its contact state when an intruder places a strong sabotage magnet near the detector.

The 3EOL device connection type is based on measuring the total loop resistance to determine the device state and events. The device can detect the following events: door opening/closing, magnetic masking, line short circuit, and line break.

The wiring diagram below shows the device's switches and resistors in the loop.

Operating principle

The device can have the following states:

Door open. The magnet is far from the detector:

  • NO reed switch (masking) — open → 9.1 kΩ resistor is in the loop
  • NO reed switch (opening) — open → 4.7 kΩ resistor is in the loop

Total loop resistance: 16.0 kΩ.

Door closed. The magnet is close to the detector:

  • NO reed switch (masking) — open → 9.1 kΩ resistor is in the loop
  • NO reed switch (opening) — closed → shunts the 4.7 kΩ resistor

Total loop resistance: 11.3 kΩ.

Magnetic masking. If an intruder places their own strong magnet near the detector to keep the opening NO reed switch closed, the masking NO reed switch also responds to this magnet and closes. As a result, the loop resistance changes to an atypical value, and the system triggers a masking alarm. The reed switches operate as follows:

  • NO reed switch (masking) — closed → shunts the 9.1 kΩ resistor
  • NO reed switch (opening) — closed → shunts the 4.7 kΩ resistor

Total loop resistance: 2.2 kΩ.

Line integrity. The line is shorted or broken:

  • Line short circuit — zero resistance in the loop
  • Line break — infinite resistance in the loop

All device states and loop resistances are listed in the table below.

State

Resistance, kΩ

Door open

16.0

Door closed

11.3

Magnetic masking

2.2

Short circuit

0

Line break

Infinity

In an Ajax system, if the device in armed mode detects a door or window being opened or closed, it instantly sends an alarm to the hub via the integration module. The hub activates the sirens added to the system, runs scenarios, and notifies users and the monitoring company of the event. All device events are recorded in the event feed in Ajax apps.

If a sabotage magnet is detected, users and the monitoring station receive a masking notification. The system allows users to select when the device should detect magnetic masking: always or only when the detector is in armed mode.

Sending events to the monitoring station

An Ajax system can transmit alarms to the Ajax PRO Desktop app and the monitoring station in the formats of SurGard (Contact ID), SIA (DC-09), ADEMCO 685, and other protocols.

The device connected to an Ajax integration module can transmit the following events:

  1. Opening sensor (opening NO reed switch) alarm / recovery.
  2. Magnetic masking sensor (masking NO reed switch) alarm / recovery.
  3. Line break / recovery (tamper alarm / recovery).
  4. Line short circuit.
  5. Permanent deactivation / activation of the device.
  6. One-time deactivation / activation of the device.

When an alarm is received, a monitoring station operator knows what has happened and exactly where to dispatch a rapid response unit. Ajax device addressability allows sending events to Ajax PRO Desktop and the monitoring station with the device type, name, security group, and virtual room specified. The list of transmitted parameters may vary depending on the monitoring software type and the selected communication protocol.

Selecting an installation site

When choosing a location for installing Ajax Superior DoorProtect Flush (3EOL), consider the parameters that affect its operation:

  • Surface material (ferromagnetic or non-ferromagnetic).
  • Distance between the detector and the magnet.
  • Levelness of the surfaces on which the detector and the magnet are installed.

When designing the system, be sure to follow the placement recommendations. Only qualified professionals can design and install an Ajax system. A list of recommended partners is available here.

Installation recommendations

The magnet position relative to the detector depends on the installation type and location, as well as the surface material. For any installation type, the detector and the magnet must be positioned exactly opposite each other and at the same level.

The detector must be installed on the fixed part of the door/window (e.g., the frame), while the magnet must be installed on the movable part.

Concealed (flush) mounting on ferromagnetic surfaces

If the detector is installed on a ferromagnetic surface:

  • The distance between the detector and the magnet must not exceed 3 mm 0.12 inch.
  • To install the magnet, use the flush-mount enclosure for mounting on ferromagnetic surfaces (the smaller one).
  • The distance between the detector and a third-party electromagnet (such as a magnetic door lock) must be greater than 4 inches.
Concealed (flush) mounting on ferromagnetic surfaces

Concealed (flush) mounting on non-ferromagnetic surfaces

If the detector is installed on a non-ferromagnetic surface:

  • The distance between the detector and the magnet must not exceed 0.12 inch.
  • To install the magnet, use the flush-mount enclosure for mounting on non-ferromagnetic surfaces (the bigger one).
  • The distance between the detector and a third-party electromagnet (such as a magnetic door lock) must be greater than 4 inches.
Concealed (flush) mounting on non-ferromagnetic surfaces

Surface mounting on ferromagnetic surfaces

If the detector is installed on a ferromagnetic surface:

  • The distance between the detector and the magnet must not exceed 0.12 inch.
  • To install the detector and the magnet, use the spacers.
  • The distance between the detector and a third-party electromagnet (such as a magnetic door lock) must be greater than 4 inches.
Surface mounting on ferromagnetic surfaces

Surface mounting on non-ferromagnetic surfaces

If the detector is installed on a non-ferromagnetic surface:

  • The distance between the detector and the magnet must not exceed 0.12 inch.
  • The distance between the detector and a third-party electromagnet (such as a magnetic door lock) must be greater than 4 inches.
Surface mounting on ferromagnetic surfaces

How not to install the device

  1. With the magnet installed at a distance that does not comply with the recommendations. This may result in false alarms or detector malfunctions: the detector will not respond to door/window closing and opening.
  2. On ferromagnetic surfaces without using the spacers (only for surface mounting).
  3. In premises with temperature and humidity beyond the permissible limits. This may damage the device.
  4. Near other magnets. This may result in false alarms caused by magnetic masking detection.
  5. Asymmetrically positioned relative to the magnet.

Preparing for installation

Cable arrangement

When preparing to run cables, check the electrical and fire safety regulations in your region. Strictly follow these standards. Tips for running cables are available in the article.

Cable routing

Before installation, refer to the Selecting an installation site section. Do not deviate from the system design. Failure to follow the basic installation rules and the recommendations in this manual may result in incorrect operation or loss of connection to the device.

Ensure a minimum distance of 20 inches between device signal cables and power cables when routing them in parallel. If the cables cross, maintain a 90° angle between them. Observe the permissible cable bending radius. Otherwise, there is a risk of damaging or breaking the conductor. Tips for cable routing are available in this article.

Preparing cables for connection

The detector is supplied with a 32.8 ft connection cable. To prepare the cable, remove the cable insulation layer and strip the wires with a special insulation stripper. The wire ends inserted into the device terminals must be tinned or crimped with a sleeve. This ensures a reliable connection and protects the conductor from oxidation. Tips for preparing the cables are available in the article.

Installation

The detector must be installed on the fixed part of the door/window (e.g., the frame), while the magnet must be installed on the movable part.

Concealed (flush) mounting

  1. Drill holes of the following dimensions in the door edge and the door frame:

    • ⌀10 × 30 mm — for the detector

    • ⌀10 × 10 mm — for the magnet, if installed on a ferromagnetic surface

    • ⌀10 × 18 mm — for the magnet, if installed on a non-ferromagnetic surface

    • ⌀0.39″ × 1.18″ — for the detector

    • ⌀0.39″ × 0.39″ — for the magnet, if installed on a ferromagnetic surface

    • ⌀0.39″ × 0.71″ — for the magnet, if installed on a non-ferromagnetic surface

    Concealed (flush) mounting
  2. Check the cable path and prepare all necessary holes for cable routing. The cable dimensions are as follows:

    • ⌀3 mm +0.2 mm, 10 m length

    • ⌀0.12″ +0.008″, 32.8 ft length

  3. Install the detector in the detector flush-mount enclosure.

    Concealed (flush) mounting
  4. Install the magnet in the magnet flush-mount enclosure. Use the magnet enclosure designed for the type of door material on which the device is installed.

    Concealed (flush) mounting
  5. Route the detector cable according to the planned path.

  6. Install the detector at the prepared location and secure it with the bundled screws using all fixing points.

    Concealed (flush) mounting
  7. Install the magnet at the prepared location and secure it with the bundled screws using all fixing points.

    Concealed (flush) mounting
  8. Ensure that the detector and the magnet are installed according to the Installation recommendations.

  9. Connect the detector cable to the integration module. One wire must be connected to the zone terminal, and the other to the COM terminal. Use any available zone terminal.

    Concealed (flush) mounting
    Concealed (flush) mounting
  10. Add the device to the system: add it to the integration module and configure its settings.

  11. Run the device functionality test.

Surface mounting

  1. Place the detector and magnet surface-mount enclosures at the planned installation location to check the installation layout. Check how cables would be routed. Use the spacers if the device is to be installed on a ferromagnetic material or to align the detector with the magnet.

  2. Open the detector and magnet surface-mount enclosures by pushing the release latches and removing the mounting panels.

    Surface mounting
  3. Secure the detector mounting panel to the surface with the bundled screws using all fixing points. Use the spacers if necessary.

  4. Secure the magnet mounting panel to the surface with the bundled screws using all fixing points. Use the spacers if necessary.

  5. Insert the detector and the magnet in the corresponding mounting panels.

    Surface mounting
  6. Route the detector cable according to the planned path.

  7. If the cable must be routed from the side of the detector, make an appropriate hole in the detector cover.

  8. Install the detector and magnet covers.

    Surface mounting
  9. Ensure the detector and the magnet are installed according to the Installation recommendations.

  10. Connect the detector cable to the integration module. One wire must be connected to the zone terminal, and the other to the COM terminal. Use any available zone terminal.

    Surface mounting
    Surface mounting
  11. Add the device to the system: add it to the integration module and configure its settings.

  12. Run the device functionality test.

Adding to the system

If the device is used in an Ajax system, follow the steps in the subsections below to add the device. If the device is used in a third-party system, refer to the instructions for adding the device to that system.

Before adding the device

  1. Install an Ajax app.
  2. Log in to a PRO account or create a new one.
  3. Select a space or create a new one.
  4. Add at least one virtual room.
  5. Add a compatible hub to the space. Ensure the hub is switched on and has internet access via Ethernet, Wi-Fi, and/or mobile network.
  6. Check the states in the Ajax app to ensure that the space is disarmed and the hub is not starting an update.
  7. Add the Ajax integration module to the system.

Adding the device to the Ajax integration module

  1. In an Ajax app, go to the Devices HubFilled-M tab.
  2. Find the integration module to which the device is connected.
  3. Select Devices under the module tile.
  4. Tap Add device.
  5. Enter a name for the device.
  6. Select the wired input to which the device is physically connected.
  7. Select a virtual room.
  8. Tap Add device. The device will be added within 30 seconds.

The device state update interval depends on the Jeweller or Jeweller/Fibra settings and defaults to 36 seconds.

If the connection attempt fails, ensure that the wired connection is set up correctly before trying again. If the maximum number of devices has already been added to the hub, an error notification appears when you try to add another device.

Setting up the device

Once the device is connected and added to the Ajax integration module, configure it to ensure correct operation.

To configure the device, in an Ajax app:

  1. Go to the Devices HubFilled-M tab.
  2. Find the integration module to which the device is connected.
  3. Select Devices under the integration module tile.
  4. Select the device from the list.
  5. Go to Settings Settings-M and configure the device according to the table below.

Sensor number

Setting

Value

N/A

Input type

3EOL

Sensor 1

Type of event

Tamper alarm

Operating mode

Bistable

R1 resistance

2.2 kΩ

Always active

Enabled

Sensor 2

Sensor mode

Detect alarms

Type of event

Intrusion

Default state

Normally closed

Operating mode

Bistable

R2 resistance

4.7 kΩ

Always active

Enabled or disabled

Sensor 3

Type of event

Masking

Default state

Normally open

Operating mode

Bistable

R3 resistance

9.1 kΩ

Always active

Enabled or disabled

Functionality testing

To perform the detection test, trigger the device. For example, open and close the door to test the opening sensor, or bring the sabotage magnet close to the detector to check the masking sensor. The sensor states will be displayed in the device states in the Ajax app.

Icons

Icon

Meaning

Bell-M

The Chime feature is enabled.

Learn more

DelayWhenLeaving-M

DelayWhenEntering-M

Entry/Exit delay is enabled.

Learn more

AlwaysActive-M

The device operates in Always active mode.

Learn more

NightMode-M

The device operates when Night mode is enabled.

Learn more

RruRemoved-M

Reporting to the monitoring station is deactivated for the device.

Learn more

WITamper-S

The state of the device's tamper button is OK.

WITamperRed-S

Device tamper alarm.

WIIntrusion-S

The state of the intrusion sensor is OK (the door/window is closed).

WIIntrusionRed-S

Intrusion alarm (the door/window is opened).

Antimasking-M

The state of the masking sensor is OK.

AntimaskingRed-M

Masking alarm.

TemporaryDeactivationAlarmsRed-M

The device is automatically disabled because the maximum number of alarms has been exceeded.

Learn more

TemporaryDeactivationTimer-M-2

The device is automatically disabled when the restoration timer expires.

Learn more

TemporaryDeactivationWholeDevice-S-red

The device is disabled by a system user.

Learn more

OneTimeDeactivationWholeDevice-S

The device is disabled until the system is disarmed.

Learn more

States

The states include information about the connected device and its operating parameters. You can view the device states in Ajax apps:

  1. Go to the Devices HubFilled-M tab.
  2. Find the integration module to which the device is connected.
  3. Select Devices under the integration module tile.
  4. Select the device from the list.

Parameter

Meaning

Malfunction

Tapping Info-M opens the list of connected device malfunctions.

The field is displayed only if a malfunction is detected.

Name of the integration module

Connection state between the integration module and the connected device:

  • Online — the device is connected to the integration module. Normal state.
  • Offline — the device is not connected to the integration module. Check the device connection.

Tamper sensor

State of the device's tamper sensor:

  • OK — the device operates normally.
  • Alert — the device has detected tampering (line break).

Intrusion sensor

State of the device's opening sensor:

  • OK — the door is closed. Normal state.
  • Alert — the door is open. Intrusion alarm.

Masking sensor

State of the device's masking sensor:

  • OK — the device operates normally.
  • Alert — the device has detected masking.

Always active sensors

Shows the device's sensors that operate in Always active mode.

Learn more

Device resistance

The total resistance of the device circuit at the moment. Measured automatically by the integration module.

Permanent deactivation

The field shows the state of the device's permanent deactivation setting:

  • No — the device operates normally and transmits all events.
  • Entirely — the space admin has completely disabled the device. It does not execute system commands or report alarms or other events.

Learn more

You can also configure device deactivation:

  • By number of alarms — the system disconnects the device when the set number of alarms is exceeded.
  • By timer — the device is automatically disconnected when the restoration timer expires.

The feature is configured in Ajax PRO apps.

Learn more

One-time deactivation

State of the device's one-time deactivation setting:

  • No — the device operates normally.
  • Entirely — the device is completely disabled until the system is disarmed. The device does not execute system commands or report alarms or other events.

Learn more

Alarm response

Operating mode

Shows how the device responds to alarms:

  • Instant alarm — the device is in armed mode, immediately responds to a threat, and raises an alarm.
  • Entry/Exit — when the delay is set, the device in armed mode starts the countdown and does not raise an alarm even if it is triggered before the countdown ends.
  • Follower — the device inherits the delays from Entry/Exit devices. However, when the Follower device is triggered individually, an alarm is immediately raised.

Entry delay

Entry delay (alarm activation delay) is the time a user has to disarm the system after entering the premises.

Learn more

Exit delay

Exit delay (arming delay) is the time a user has to leave the premises after the system is armed.

Learn more

Arm in Night mode

When the option is enabled, the device will enter armed mode when the system is set to Night mode.

Learn more

Entry delays in Night mode

Entry delay (alarm activation delay) in Night mode is the time a user has to disable Night mode after entering the premises.

Learn more

Exit delays in Night mode

Exit delay (arming delay) in Night mode is the time a user has to leave the premises after Night mode is enabled.

Learn more

Night mode delay

Entry delay in Night mode when the device is set to the Follower operating mode. It is the time a user has to disable Night mode (alarm activation delay) after the Entry/Exit device is triggered.

Learn more

Wire input

The number of the integration module zone to which the device is connected.

Device No.

The device loop (zone) number.

Settings

To change the device settings, in an Ajax app:

  1. Go to the Devices HubFilled-M tab.
  2. Find the integration module to which the device is connected.
  3. Select Devices under the integration module tile.
  4. Select the device from the list.
  5. Go to Settings Settings-M.
  6. Configure the required settings.
  7. Tap Back to save the new settings.

Setting

Meaning

Name

The device name. Displayed in the list of hub devices, SMS, and notifications in the event feed.

To change the name, tap on the text field.

The name can contain up to 24 Latin characters or up to 12 Cyrillic characters.

Room

Selecting the virtual room to which the device is assigned.

The room name is displayed in the text of SMS and notifications in the event feed.

Input type

Selecting the device connection type.

The 3EOL option must be selected for this setting.

Connection diagram

Displays the wiring diagram for connecting a device to the integration module.

It is used as a reference for an installer.

Measure sensor resistance

Allows a user to open a wizard that automatically measures the resistance of a resistor connected to the device.

Sensor 1

By default, the state of contacts for Sensor 1 is normally closed.

Type of event

The event type for the connected device.

The Tamper alarm option must be selected for this setting.

The text of notifications in the event feed and SMS, as well as the code transmitted to monitoring software, depends on the selected event type.

Operating mode

The operating mode for the connected device.

The Bistable option must be selected for this setting.

R1 resistance

The resistance of a resistor connected to Sensor 1. Measured automatically.

The 2.2 kΩ value must be selected for this setting.

Always active

When the option is enabled, the device connected to the integration module constantly detects threats and reports alarms.

This option must be enabled for Sensor 1.

Learn more

Sensor 2

Sensor mode

The sensor mode for the connected device.

The Detect alarms option must be selected for this setting.

Type of event

The event type for the connected device.

The Intrusion option must be selected for this setting.

The text of notifications in the event feed and SMS, as well as the code transmitted to monitoring software, depends on the selected event type.

Default state

The normal contact state for the connected device (when the magnet is present).

The Normally closed option must be selected for this setting.

Operating mode

The operating mode for the connected device.

The Bistable option must be selected for this setting.

R2 resistance

The resistance of a resistor connected to Sensor 2. Measured automatically.

The 4.7 kΩ value must be selected for this setting.

Always active

When the option is enabled, the device connected to the integration module constantly detects threats and reports alarms.

Learn more

Sensor 3

Type of event

The event type for the connected device.

The Masking option must be selected for this setting.

The text of notifications in the event feed and SMS, as well as the code transmitted to monitoring software, depends on the selected event type.

Default state

The normal contact state for the connected device (when the magnet is present).

The Normally open option must be selected for this setting.

Operating mode

The operating mode for the connected device:

The Bistable option must be selected for this setting.

R3 resistance

The resistance of a resistor connected to Sensor 3. Measured automatically.

The 9.1 kΩ value must be selected for this setting.

Always active

When the option is enabled, the device connected to the integration module constantly detects threats and reports alarms.

Learn more

Pulse time

Device pulse time for alarm activation:

  • 20 ms
  • 100 ms (by default)
  • 1 s

An alarm will be activated if the pulse from the device lasts longer than specified in this setting. This can be used to filter out false alarms.

Alert with siren if Sensor 1 is triggered

When the option is enabled, the sirens added to the system will sound if Sensor 1 raises an alarm.

Alert with siren if Sensor 2 is triggered

When the option is enabled, the sirens added to the system will sound if Sensor 2 raises an alarm.

Alert with siren if Sensor 3 is triggered

When the option is enabled, the sirens added to the system will sound if Sensor 3 raises an alarm.

Alert with siren if device is shorted out

If the option is enabled, the sirens connected to the system are activated when a short circuit is detected.

Chime settings

Configuring the Chime feature. It is available only for devices operating in Bistable mode.

The feature is not available for sensors in Pulse mode or Always active mode.

Learn more

Alarm response

Operating mode

Selecting how this device will respond to alarms:

  • Instant alarm — the device in armed mode immediately responds to a threat and raises an alarm.
  • Entry/Exit — when the delay is set, the device in armed mode starts the countdown and does not raise an alarm even if it is triggered until the countdown ends.
  • Follower — the device inherits the delays from Entry/Exit devices. However, when the Follower device is triggered individually, an alarm is immediately raised.

Entry delay

Entry delay: 5 to 255 seconds.

Entry delay (alarm activation delay) is the time a user has to disarm the system after entering the premises.

Learn more

Exit delay

Exit delay: 5 to 255 seconds.

Exit delay (arming delay) is the time a user has to leave the premises after the system is armed.

Learn more

Arm in Night mode

When this option is enabled, the detector will enter the armed mode if the system is set to Night mode.

Learn more

Entry delays in Night mode

Entry delay in Night mode: 5 to 255 seconds.

Entry delay (alarm activation delay) in Night mode is the time a user has to disable Night mode after entering the premises.

Learn more

Exit delays in Night mode

Exit delay in Night mode: 5 to 255 seconds.

Exit delay (arming delay) in Night mode is the time a user has to leave the premises after Night mode is enabled.

Learn more

Night mode delay

Delay time in Night mode: 5 to 255 seconds.

It is the time a user has to disable Night mode (alarm activation delay) after the Entry/Exit device is triggered.

The setting is displayed if the device is set to the Follower operating mode and the Arm in Night mode option is enabled.

Learn more

Monitoring

Allows a user to open the monitoring setting menu:

  • Send events to CMS — the option allows PRO users to enable or disable sending events to monitoring software for the device. The option is enabled by default.

Monitoring settings are available only in Ajax PRO apps.

Learn more

Permanent deactivation

Allows a user to disable the device without removing it from the system.

Two options are available:

  • No — the device operates normally and transmits all events.
  • Entirely — the space admin has completely disabled the device. It does not execute system commands or report alarms or other events.

Learn more

A user can also configure device deactivation:

  • By number of alarms — the system disconnects the device when the set number of alarms is exceeded.
  • By timer — the device is automatically disconnected when the restoration timer expires.

The feature is configured in Ajax PRO apps.

Learn more

One-time deactivation

Allows a user to disable the device until the system is disarmed.

Two options are available:

  • No — the device operates normally and transmits all events.
  • Entirely — the device is completely disabled until the system is disarmed. The device does not execute system commands or report alarms or other events.

Learn more

Delete device

Allows a user to delete the device from the module.

Chime on opening

Chime is an audible signal that informs users when opening detectors are triggered while the system is disarmed. The feature is used, for example, in stores to alert employees when someone enters the premises.

The feature is configured in two stages: setting up the sirens and setting up the opening detectors.

Configuring a device connected to the integration module

  1. Go to the Devices HubFilled-M tab.
  2. Find the integration module to which the device is connected.
  3. Tap Devices under the integration module tile.
  4. Select the device from the list.
  5. Go to the device Settings .
  6. Select the Chime settings option.
  7. Enable the If device is triggered option.
  8. Adjust the chime sound: 1 to 4 short beeps. Once the sound is selected, the Ajax app will play it.
  9. Tap Back to apply the settings.

Ensure the Chime feature is enabled for the required siren in its Beep settings.

Indication

The device has no indication.

Malfunctions

When a malfunction occurs, the integration module to which the device is connected can identify the type of malfunction according to the configured sensor settings for the 3EOL connection.

If the device is connected to an Ajax integration module, a malfunction counter is displayed in the upper-left corner of the device icon in the Ajax app. Users can view malfunctions in the module states and the states of connected devices. Fields with malfunctions are highlighted in red.

A malfunction of the connected device is displayed if:

  • There is no connection between the integration module and the device (the tamper button has been triggered or the contacts are damaged).
  • The system has detected a short circuit in the device contacts.

The system can report malfunctions to the monitoring station, as well as to users via push notifications and SMS.

Maintenance

Regularly check the device's functionality. The recommended check interval is once every three months. Clean the device enclosure from dust, cobwebs, and other contaminants as needed. Use a soft, dry cloth suitable for equipment care. Do not use substances containing alcohol, acetone, gasoline, or other active solvents to clean the device.

Technical specifications

Warranty

Warranty for products manufactured by Limited Liability Company "Ajax Systems Manufacturing" is valid for two years from the date of purchase.

If the device does not operate properly, we recommend contacting the support service first, as most technical issues can be resolved remotely.

Contact Technical Support:

Manufactured by "AS Manufacturing" LLC

Need help?

Explore the full potential of an Ajax system through detailed manuals, articles, tools, and FAQs. For immediate assistance, our AI-powered chatbot and professional technical support team are available 24/7.

Ajax Systems